{"product_id":"ge-fanuc-me98mbp001-proficy-machine-edition-communications-software","title":"GE Fanuc ME98MBP001 Proficy Machine Edition Communications Software","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc ME98MBP001\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eME98MBP001\u003c\/strong\u003e Proficy Machine Edition Communication Software, operates as a dedicated programming and configuration component for managing industrial control communications within Proficy automation platforms.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eME98MBP001\u003c\/strong\u003e: Base model identifier for the Proficy Machine Edition software license and communications toolkit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProficy Platform\u003c\/strong\u003e: Designed for integration with GE Fanuc PLC and DCS control environments for protocol setup and diagnostic management.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eME98MBP001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSubject to factory documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eSoftware media (digital\/physical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eN\/A (Software License)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard workstation environment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePC system resource dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCommunication Software License\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eProficy Machine Edition environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe ME98MBP001 software suite provides the necessary configuration interfaces for establishing deterministic data exchange protocols across industrial networks. It enables the definition of network parameters, including station addresses, bus timing, and packet definitions for Profinet and EtherNet\/IP architectures. Firmware flash compatibility and protocol stack management are facilitated through this software, ensuring that connected I\/O devices and controllers maintain synchronized communication. Users must ensure that the software version is verified against the hardware firmware revision to prevent mismatches in protocol implementation during system integration.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is the ME98MBP001 software required to configure communication parameters on legacy GE Fanuc hardware?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The software provides the interface for defining communication settings and register mapping that are not accessible through front-panel controls on standard controllers.\u003c\/p\u003e\n\u003cp\u003eQ: Can the software license be transferred between different programming workstations?\u003c\/p\u003e\n\u003cp\u003eA: Transfer procedures must follow the licensing agreement specifications. Typically, this involves deactivating the license on the source machine before activation on the target system.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Requirements:\u003c\/strong\u003e Verify that the programming workstation meets the minimum OS and hardware specifications required by the Proficy Machine Edition environment before installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation:\u003c\/strong\u003e Run the setup utility with administrative privileges. Ensure that all necessary communication drivers for the specific network interface cards (NIC) are selected during the installation process.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProject Setup:\u003c\/strong\u003e Define the communication driver in the project navigator to match the physical hardware and protocol being utilized in the field.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValidation:\u003c\/strong\u003e After configuration, perform a communication test (ping\/scan) to verify connectivity between the workstation and the target controller before initiating project deployment or online monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52638868242744,"sku":"ME98MBP001","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/VMIACC-5595-2082.jpg?v=1784017256","url":"https:\/\/www.automodulexpert.com\/products\/ge-fanuc-me98mbp001-proficy-machine-edition-communications-software","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}