{"product_id":"ge-is200jpdeg1abb-dc-battery-distribution-board","title":"GE IS200JPDEG1ABB DC Battery Distribution Board","description":"\u003cp\u003eConfigured for power regulation and distribution in Mark VIe Turbine Control Systems, the \u003cstrong\u003eGE IS200JPDEG1ABB\u003c\/strong\u003e (\u003cstrong\u003eIS200JPDEG1\u003c\/strong\u003e DC Battery Distribution Board) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200JPDEG1ABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.55 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard PDM-style drive assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDetermined by system load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Filtering\u003c\/td\u003e\n\u003ctd\u003e30 A input filters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eDual 50-pin diagnostic connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit Protection\u003c\/td\u003e\n\u003ctd\u003eIntegrated DC circuit breakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus and Deterministic Network Integration\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eIS200JPDEG1ABB\u003c\/strong\u003e architecture maintains signal integrity within the Mark VIe I\/O environment through optimized backplane bus communication velocity. The board interfaces with the PPDA Input\/Output Pack to facilitate deterministic feedback transmission, ensuring that voltage distribution levels are synchronized across the control network. Firmware flash compatibility is managed through the I\/O core, allowing for precise monitoring of power states and transition events. The logic board utilizes high-density I\/O scaling to manage power transients, ensuring that deterministic network response times are preserved during active power distribution cycles.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the board support field-configurable maintenance settings?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the assembly includes customizable switches and voltage limiting components, such as resistors and diodes, to facilitate controlled maintenance and power isolation procedures.\u003c\/p\u003e\n\u003cp\u003eQ: What is the primary function of the dual 50-pin connectors?\u003c\/p\u003e\n\u003cp\u003eA: The connectors provide dedicated diagnostic feedback channels to the PPDA Input\/Output Pack, allowing for real-time monitoring of DC distribution status and breaker health.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure all DC power sources are isolated and locked out before installation of the board into the PDM-style drive assembly.\u003c\/li\u003e\n\u003cli\u003eSecure the board using the integrated metal mounting bracket, ensuring proper chassis grounding to minimize impedance paths.\u003c\/li\u003e\n\u003cli\u003eConnect the 50-pin diagnostic ribbon cables to the designated interface headers, verifying that the connector locks are fully seated to prevent intermittent signal loss.\u003c\/li\u003e\n\u003cli\u003eVerify the integrity of the 30 A input filters and circuit breakers prior to re-energizing the DC distribution bus.\u003c\/li\u003e\n\u003cli\u003ePerform a voltage validation check at the output terminals to ensure levels are consistent with system load requirements and free of ground faults.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52555175526712,"sku":"IS200JPDEG1ABB","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IS200JPDEG1AAA_b6fb9ffd-e37d-4d61-b203-b0ab1951ee87.jpg?v=1760510247","url":"https:\/\/www.automodulexpert.com\/products\/ge-is200jpdeg1abb-dc-battery-distribution-board","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}