{"product_id":"ge-krautkramer-10bt-mic-hardness-tester","title":"GE Krautkramer 10BT MIC Hardness Tester","description":"\u003cp\u003eConfigured for precision material testing in industrial maintenance, the \u003cstrong\u003eGE Krautkramer 10BT MIC\u003c\/strong\u003e (often referenced as the \u003cstrong\u003eMIC 10\u003c\/strong\u003e series UCI Hardness Tester) provides direct physical measurement of material surface integrity using the Ultrasonic Contact Impedance (UCI) method.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e10BT MIC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Krautkramer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 0.30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e160 mm x 70 mm x 45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e2 x 1.5 V AA batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Method\u003c\/td\u003e\n\u003ctd\u003eUltrasonic Contact Impedance (UCI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness Scales\u003c\/td\u003e\n\u003ctd\u003eVickers (HV), Rockwell (HRC\/HRB), Brinell (HB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Signal Processing\u003c\/h3\u003e\n\u003cp\u003eThe 10BT MIC operates by measuring the frequency shift of a rod excited into ultrasonic resonance upon contact with the test material. Accurate hardness derivation requires consistent probe scaling and validation against reference standards. Cross-talk suppression within the internal circuitry ensures that signal noise from the 3-pin XLR probe interface does not interfere with the precision of the Vickers diamond indenter displacement measurement. Calibration parameters for standard steel alloys are pre-programmed; however, field users must ensure proper gap validation and surface preparation to maintain the integrity of the UCI measurement loop.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 10BT MIC support hot-swapping of UCI probes?\u003c\/p\u003e\n\u003cp\u003eA: No. Always power down the instrument before disconnecting or connecting a probe to the 3-pin XLR interface to prevent potential electrical damage to the probe excitation circuitry.\u003c\/p\u003e\n\u003cp\u003eQ: What is the significance of the 600 ohm output impedance mentioned in some documentation?\u003c\/p\u003e\n\u003cp\u003eA: The stated impedance refers to the signal output characteristics for data transfer via the interface port. This ensures compatibility with standard peripherals and data logging devices without signal distortion.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurface Preparation:\u003c\/strong\u003e Ensure the test surface is clean, smooth, and free of coatings or oxidation. The UCI method requires intimate contact between the Vickers indenter and the base material for accurate results.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe Positioning:\u003c\/strong\u003e Maintain perpendicular alignment of the probe to the surface. Use guiding devices or test supports to ensure steady probe guidance, especially when testing on curved or difficult-to-access geometries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibration:\u003c\/strong\u003e Perform a calibration check on a known hardness reference block before each shift. Adjust calibration parameters if the material being tested deviates significantly from standard non-alloyed steel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e While the device is battery-operated, ensure it is protected from high-static environments which could potentially discharge through the sensitive probe electronics.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52638841504056,"sku":"10BT MIC","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/10BT_MIC.jpg?v=1784017269","url":"https:\/\/www.automodulexpert.com\/products\/ge-krautkramer-10bt-mic-hardness-tester","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}