{"product_id":"ge-mlj1005b010h00c-synchronism-check-relay","title":"GE MLJ1005B010H00C Synchronism Check Relay","description":"\u003cp\u003eConfigured for power grid synchronization and parallel interconnection, the \u003cstrong\u003eGE MLJ1005B010H00C\u003c\/strong\u003e (\u003cstrong\u003eMLJ1005B010H00C\u003c\/strong\u003e Synchronism Check Relay) provides direct physical and electrical execution of bus-to-line phase matching and voltage window monitoring.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMLJ\u003c\/strong\u003e: Base Model Synchronism Check Relay series\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1005\u003c\/strong\u003e: Core logic and synchronization processing module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eB\u003c\/strong\u003e: Hardware revision\/housing specification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e010\u003c\/strong\u003e: Voltage and phase angle threshold configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eH\u003c\/strong\u003e: High-range control power supply\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e00C\u003c\/strong\u003e: Auxiliary I\/O and communication output settings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMLJ1005B010H00C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eStandard Industrial Manufacturing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial standard range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eDigital Synchronism Check\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFail-Safe State Execution and Galvanic Isolation\u003c\/h3\u003e\n\u003cp\u003eThe MLJ1005B010H00C relay is designed for high-integrity grid applications, incorporating internal diagnostic routines to ensure fail-safe state execution. The unit features galvanic isolation between sensing inputs and control outputs, preventing high-voltage transients from the bus potential transformers (PT) from propagating into the safety control logic. If the sensed voltage difference, phase angle, or frequency drift exceeds the programmed limits, the relay internally inhibits the closing command to the circuit breaker, maintaining a safe state until synchronization criteria are met.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: What is the primary purpose of the synchronism check function in this relay?\u003c\/p\u003e\n\u003cp\u003eA: The relay monitors the voltage magnitude, frequency, and phase angle difference between two sources (e.g., bus and line). It only permits breaker closure when these parameters fall within safe, predefined limits to prevent damage caused by out-of-phase connection of two power systems.\u003c\/p\u003e\n\u003cp\u003eQ: How is the relay output configured to prevent breaker closure during an error condition?\u003c\/p\u003e\n\u003cp\u003eA: The internal output contact serves as an interlock in the breaker closing circuit. During a failed check or internal diagnostic error, the relay maintains an open contact state, physically preventing the energization of the breaker closing coil.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003ePower down the relay control circuit and disconnect PT inputs before performing installation to avoid exposure to high-voltage potentials.\u003c\/li\u003e\n\u003cli\u003eTerminate bus and line PT inputs using shielded, twisted-pair cabling to minimize common-mode noise and prevent phase angle measurement errors.\u003c\/li\u003e\n\u003cli\u003eVerify that the relay enclosure is firmly grounded to the control panel chassis to ensure proper shielding and surge protection performance.\u003c\/li\u003e\n\u003cli\u003eKeep all measurement wiring separated from high-current power cables by a minimum distance of 200 mm to maintain signal integrity.\u003c\/li\u003e\n\u003cli\u003ePerform a functional verification test using a secondary injection test set to simulate various phase angle and voltage conditions before placing the relay into active service.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52649679356216,"sku":"MLJ1005B010H00C","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/MLJ1005B010H00C.jpg?v=1784189478","url":"https:\/\/www.automodulexpert.com\/products\/ge-mlj1005b010h00c-synchronism-check-relay","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}