{"product_id":"ge-multilin-869-ep5p5b5hrranngmpbbsennbn-motor-protection-relay","title":"GE Multilin 869-EP5P5B5HRRANNGMPBBSENNBN Motor Protection Relay","description":"\u003cp\u003eConfigured for high-performance protection and control of medium to large motors, the \u003cstrong\u003eGE Multilin 869-EP5P5B5HRRANNGMPBBSENNBN\u003c\/strong\u003e (\u003cstrong\u003e869-EP5P5B5HRRANNGMPBBSENNBN\u003c\/strong\u003e Motor Protection Relay) provides direct physical and electrical execution of motor management logic and diagnostic monitoring.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e869\u003c\/strong\u003e: Base model series identifier for the Multilin Motor Protection System.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eE...NBN\u003c\/strong\u003e: Configuration string defining specific I\/O, communication, and protection feature sets tailored for motor application environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e869-EP5P5B5HRRANNGMPBBSENNBN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Multilin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSubject to factory documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard 869 series rack-mount form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial standard environment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSubject to auxiliary control voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Functions\u003c\/td\u003e\n\u003ctd\u003eOverload, underload, phase imbalance, thermal, ground fault\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eReal-time health tracking, high-resolution oscillography\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe 869-EP5P5B5HRRANNGMPBBSENNBN relay supports deterministic communication protocols necessary for time-critical motor protection and synchrophasor data measurement (IEEE C37.118). Integration into network architectures requires strict adherence to bus communication velocity limits to ensure that trip signals and status updates are processed without delay. Firmware flash compatibility must be confirmed against the system master to maintain protocol stack integrity. The relay’s internal processing architecture isolates high-speed fault event recording from supervisory data traffic, ensuring that oscillography data does not compromise protection trip timing.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 869-EP5P5B5HRRANNGMPBBSENNBN be hot-swapped while the motor is running?\u003c\/p\u003e\n\u003cp\u003eA: No. The protection system must be isolated from CT inputs and control power before removal to avoid unintentional motor trips or damage to the internal signal sampling circuitry.\u003c\/p\u003e\n\u003cp\u003eQ: How is the synchrophasor measurement functionality utilized in this relay?\u003c\/p\u003e\n\u003cp\u003eA: The IEEE C37.118 synchrophasor measurement enables time-synchronized reporting of electrical parameters, allowing for wide-area monitoring and post-event analysis when integrated with Phasor Data Concentrators (PDCs).\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Secure the relay into the panel cutout using the provided mounting hardware. Ensure the 9 kg mass is adequately supported to prevent structural strain on the enclosure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Terminate phase current and ground current inputs using appropriately sized lugs. Use shielded twisted-pair cabling for all communication and analog connections to minimize electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the relay chassis ground terminal directly to the cabinet protective earth (PE) bus. A low-impedance ground bond is necessary to ensure the effectiveness of internal surge protection elements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValidation:\u003c\/strong\u003e Before placing the motor into service, verify the configuration of all protection setpoints and confirm the mapping of input\/output contacts to the control system logic.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52638869782840,"sku":"869-EP5P5B5HRRANNGMPBBSENNBN","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/869-EP5P5B5HRRANNGMPBBSENNBN1.jpg?v=1784017269","url":"https:\/\/www.automodulexpert.com\/products\/ge-multilin-869-ep5p5b5hrranngmpbbsennbn-motor-protection-relay","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}