{"product_id":"ge-multilin-t60-g01-hch-f8h-h67-m8f-p6d-u6d-w6c-transformer-protection-relay","title":"GE Multilin T60-G01-HCH-F8H-H67-M8F-P6D-U6D-W6C Transformer Protection Relay","description":"\u003cp\u003eThe \u003cstrong\u003eGE Multilin T60-G01-HCH-F8H-H67-M8F-P6D-U6D-W6C\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eT60\u003c\/strong\u003e Transformer Protection Relay, operates as a dedicated hardware component for dual-slope differential protection and power transformer asset monitoring within substation automation platforms.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCode Position\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOption Designator\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunctional Description\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Family\u003c\/td\u003e\n\u003ctd\u003eT60\u003c\/td\u003e\n\u003ctd\u003eMultilin Universal Relay (UR) Transformer Protection Platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Variant\u003c\/td\u003e\n\u003ctd\u003eG01\u003c\/td\u003e\n\u003ctd\u003eCPU Module with 10Base-T Ethernet \u0026amp; RS485 Communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware Option\u003c\/td\u003e\n\u003ctd\u003eHCH\u003c\/td\u003e\n\u003ctd\u003eAdvanced Protection Suite with Harmonics and Loss-of-Life Monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount \u0026amp; Display\u003c\/td\u003e\n\u003ctd\u003eF8H\u003c\/td\u003e\n\u003ctd\u003eFull Color LCD Front Panel Display with Keypad (8U Chassis)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eH67\u003c\/td\u003e\n\u003ctd\u003eHigh-Voltage Universal AC\/DC Power Supply Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital I\/O 1\u003c\/td\u003e\n\u003ctd\u003eM8F\u003c\/td\u003e\n\u003ctd\u003eDigital I\/O Module with 8 Form-A Outputs and Fast Response Contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCT\/VT Module 1\u003c\/td\u003e\n\u003ctd\u003eP6D\u003c\/td\u003e\n\u003ctd\u003eStandard Phase Current Transformer \u0026amp; Voltage Transformer Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCT\/VT Module 2\u003c\/td\u003e\n\u003ctd\u003eU6D\u003c\/td\u003e\n\u003ctd\u003eSecondary Winding Phase CT \u0026amp; Neutral CT Processing Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary I\/O\u003c\/td\u003e\n\u003ctd\u003eW6C\u003c\/td\u003e\n\u003ctd\u003eTransducer Analog I\/O \u0026amp; Transducer Interface Hardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eT60-G01-HCH-F8H-H67-M8F-P6D-U6D-W6C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Multilin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eCanada \/ USA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e18.5 lbs (8.39 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e8U standard 19-inch rack-mount chassis (355 x 483 x 272 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e20 W nominal (40 W maximum under full digital load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Logic\u003c\/td\u003e\n\u003ctd\u003eDual-slope differential with breakpoint restraint, thermal overload, overexcitation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurements\u003c\/td\u003e\n\u003ctd\u003eIEEE C37.118 compliant Synchrophasor telemetry, event recording, fault oscillography\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Limits\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Interface\u003c\/td\u003e\n\u003ctd\u003eColor LCD display with navigation keypad and front RS-232 serial interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Backplane \u0026amp; Bus Synchronization\u003c\/h3\u003e\n\u003cp\u003eThe T60 unit utilizes the Multilin Universal Relay modular backplane architecture to route sampled analog current and voltage data between high-speed signal processing channels. Backplane bus communication velocity architecture ensures microsecond-level synchronization across multiple CT\/VT sampling modules to process dual-slope differential restraint calculations. Internal logic supports firmware flash compatibility to maintain uninterrupted execution of IEEE C37.118 synchrophasor streaming, fault oscillography recording, and loss-of-life thermal algorithms during severe grid fault transients.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What power supply thresholds are required for the H67 hardware option on the T60 relay?\u003c\/p\u003e\n\u003cp\u003eA: The H67 option designates a high-voltage universal auxiliary power supply designed to accept operating inputs ranging from 110 to 250 VDC or 110 to 230 VAC without manual jumper selection.\u003c\/p\u003e\n\u003cp\u003eQ: How does the T60 manage channel isolation across its CT\/VT input cards?\u003c\/p\u003e\n\u003cp\u003eA: Each current transformer and voltage transformer input channel is galvanically isolated from internal digital processing buses and adjacent modules, preventing ground loops and protecting signal conversion circuitry from high-voltage substation surges.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Mounting\u003c\/strong\u003e: Mount the 8U chassis securely into a standard 19-inch instrument rack using all designated corner mounting holes. Ensure unblocked airflow around the top and bottom chassis heatsink channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Connection\u003c\/strong\u003e: Connect the dedicated rear chassis grounding lug directly to the substation main ground grid using a short, low-impedance braided copper strap (minimum 10 AWG).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCT Cable Terminal Shorting\u003c\/strong\u003e: Pass current transformer secondary connections through shorting terminal blocks immediately prior to entering the relay terminal block. Verify tight screw torque on all current loops before energizing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet and Serial Shielding\u003c\/strong\u003e: Route fiber optic or shielded twisted-pair communication cables in grounded metallic conduits isolated from high-voltage AC current lines to suppress high-frequency electromagnetic interference.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52718847623480,"sku":"T60-G01-HCH-F8H-H67-M8F-P6D-U6D-W6C","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/T60-G01-HCH-F8H-H67-M8F-P6D-U6D-W6C1.jpg?v=1785315418","url":"https:\/\/www.automodulexpert.com\/products\/ge-multilin-t60-g01-hch-f8h-h67-m8f-p6d-u6d-w6c-transformer-protection-relay","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}