{"product_id":"ge-se4002s1t2b5-discrete-output-module","title":"GE SE4002S1T2B5 Discrete Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE SE4002S1T2B5\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eSE4002S1T2B5\u003c\/strong\u003e Discrete Output Module, operates as a dedicated hardware component for signal transmission and control loop execution within industrial control network platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSE4002S1T2B5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eStandard Industrial Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e100 mm x 200 mm x 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC Nominal, 8 A Total Output Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eDiscrete (Digital)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Configuration\u003c\/td\u003e\n\u003ctd\u003eHigh Side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Current per Channel\u003c\/td\u003e\n\u003ctd\u003e0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e1500 V (input to output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eTerminal Block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet and EtherNet\/IP Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eConfigured for high-speed industrial operations, the module manages backplane bus communication velocity licenses to interface directly with deterministic network topologies. Profinet and EtherNet\/IP protocol layers process cyclic data exchanges without packet collision overhead. Firmware flash compatibility ensures seamless integration during system upgrades, while I\/O density scaling allows dynamic adjustment across expanding rack architectures without degrading bus cycle execution times.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the primary output voltage and current specifications for this module? A: The module supports a 24 VDC output voltage across 32 discrete channels, providing up to 0.5 A per channel with a total output current capacity of 8 A.\u003c\/p\u003e\n\u003cp\u003eQ: Is this discrete output module capable of hot-swap operations in active racks?\u003c\/p\u003e\n\u003cp\u003eA: Hot-swap capability is supported provided that backplane power is sequenced correctly and chassis grounding pins establish physical contact prior to signal engagement.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure the chassis slot is clear of particulate contamination before inserting the module along the designated mechanical guide rails. Secure retention screws to the specified torque limit to establish a low-impedance ground path to the DIN rail or backplane chassis. Verify that ambient enclosure temperatures do not exceed the operating boundary of -20 deg C to +70 deg C. Route output control cabling away from high-voltage AC conduits to minimize electromagnetic induction on internal communication circuits.\u003c\/p\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52682046112056,"sku":"SE4002S1T2B5","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/SE3006.jpg?v=1784794562","url":"https:\/\/www.automodulexpert.com\/products\/ge-se4002s1t2b5-discrete-output-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}