{"product_id":"general-electric-469-p5-hi-a20-e-h-motor-management-relay","title":"General Electric 469-P5-HI-A20-E-H Motor Management Relay","description":"\u003cp\u003eThe \u003cstrong\u003eGeneral Electric 469-P5-HI-A20-E-H\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e469\u003c\/strong\u003e Motor Management Relay, operates as a dedicated hardware component for multi-stage motor protection and deterministic process monitoring within industrial drive networks.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e469\u003c\/strong\u003e: Base Model Motor Management Relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eP5\u003c\/strong\u003e: Standard protection suite (5 A phase CT inputs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHI\u003c\/strong\u003e: High-range control power supply (standard auxiliary input)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA20\u003c\/strong\u003e: Analog I\/O and communication configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eE\u003c\/strong\u003e: Ethernet communication support\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eH\u003c\/strong\u003e: High-integrity terminal and enclosure hardware\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e469-P5-HI-A20-E-H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e7.36 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e21.5 cm x 23 cm x 25 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial standard range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eHI (High range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Inputs\u003c\/td\u003e\n\u003ctd\u003e5 A phase CTs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eEthernet, Analog I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe 469 relay utilizes deterministic networking to facilitate real-time monitoring and protection control. It supports high-speed data transmission for trip signals, enabling rapid fault clearance for motor overload, phase unbalance, and rotor stall conditions. The integration of deterministic communication pathways ensures that protection events are prioritized over routine diagnostic data, maintaining the integrity of the motor control logic across the station bus. This architecture supports firmware flash compatibility, allowing for updates to protection algorithms while maintaining synchronization with the global timing clock of the control system.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: How does the 469 relay differentiate between a starting condition and a locked-rotor fault?\u003c\/p\u003e\n\u003cp\u003eA: The relay utilizes a dynamic thermal model that tracks the motor's heating state based on measured current and time. During start-up, the relay permits a temporary higher current threshold according to a pre-defined thermal curve; if the current persists beyond the start-up time limit without the motor reaching nominal speed, the relay triggers a locked-rotor protection trip.\u003c\/p\u003e\n\u003cp\u003eQ: Is it possible to perform firmware updates without removing the relay from the cabinet?\u003c\/p\u003e\n\u003cp\u003eA: Yes, firmware updates can be performed via the rear Ethernet or RS485 communication ports. Ensure the relay is in a safe, non-operational state and that the control power remains stable throughout the entire flash sequence to prevent corruption of the non-volatile memory.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003ePower down the motor control center (MCC) and verify isolation of all primary and auxiliary power sources before handling the relay to prevent electrical shock.\u003c\/li\u003e\n\u003cli\u003eEnsure the relay chassis is bonded to the station ground bus using a low-impedance copper conductor to mitigate the effects of electromagnetic interference and surge transients.\u003c\/li\u003e\n\u003cli\u003eTerminate all Current Transformer (CT) inputs with firm torque; verify that CT secondary circuits are never left open-circuited while primary lines are energized, as this generates hazardous high voltages.\u003c\/li\u003e\n\u003cli\u003eRoute communication and signal cables through shielded conduits, maintaining a minimum separation of 300 mm from high-voltage primary conductors to prevent inductive crosstalk.\u003c\/li\u003e\n\u003cli\u003eVerify the relay’s CT ratio settings against the physical CT nameplate values before conducting primary current injection testing to ensure accurate protection operation.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52649770287416,"sku":"469-P5-HI-A20-E-H","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/469-P5-HI-A20-E-H2.jpg?v=1784189481","url":"https:\/\/www.automodulexpert.com\/products\/general-electric-469-p5-hi-a20-e-h-motor-management-relay","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}