{"product_id":"general-electric-745-w2-p5-g5-hi-e-transformer-protection-system","title":"General Electric 745-W2-P5-G5-HI-E Transformer Protection System","description":"\u003cp\u003eThe \u003cstrong\u003eGeneral Electric 745-W2-P5-G5-HI-E\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e745\u003c\/strong\u003e Transformer Protection System, operates as a dedicated hardware component for differential protection and condition monitoring within power distribution and transformer networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e745-W2-P5-G5-HI-E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e7.52 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e21.5 cm x 23 cm x 25 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial standard range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eTransformer Protection System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe 745 system utilizes high-speed deterministic networking for substation automation and protection coordination. It supports integration into modern control platforms, enabling real-time status reporting and event logging. The module ensures deterministic execution of trip logic during fault conditions, minimizing clearing times for internal transformer faults. Furthermore, its communication architecture is designed to handle high-density data packets for waveform capture and oscillography without compromising the primary protection scan rates across the station bus.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: What is the recommended procedure for verifying the current transformer (CT) wiring and polarity during commissioning?\u003c\/p\u003e\n\u003cp\u003eA: Perform a primary injection test to confirm that the secondary currents align with the relay's internal settings. Incorrect polarity will result in a differential trip during normal load conditions; ensure all CT ratios and phase vectors are correctly entered into the relay configuration software.\u003c\/p\u003e\n\u003cp\u003eQ: How should the system be configured to handle inrush currents during transformer energization?\u003c\/p\u003e\n\u003cp\u003eA: Utilize the programmable harmonic restraint features within the 745 relay. The device detects the percentage of second-harmonic content, which is used to desensitize the differential element during transient magnetizing events, preventing nuisance tripping while maintaining sensitivity to actual internal faults.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the relay chassis is connected to a low-impedance substation ground grid to maintain safety and suppress transient surges.\u003c\/li\u003e\n\u003cli\u003eVerify that all current and voltage input circuits are secured with firm terminal torque; loose connections in CT circuits can lead to high-voltage build-up and relay damage.\u003c\/li\u003e\n\u003cli\u003eInstall the unit in an environment free from excessive vibration and corrosive gasses to preserve the integrity of internal electronic components.\u003c\/li\u003e\n\u003cli\u003eRoute signal and communication cables through dedicated, shielded conduits, keeping them at least 300 mm away from high-voltage primary conductors.\u003c\/li\u003e\n\u003cli\u003eConfirm that the control power voltage supplied to the relay matches the \"HI\" rating on the nameplate to prevent internal power supply failure.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52649490776376,"sku":"745-W2-P5-G5-HI-E","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/745-W2-P5-G5-HI-E.jpg?v=1784189482","url":"https:\/\/www.automodulexpert.com\/products\/general-electric-745-w2-p5-g5-hi-e-transformer-protection-system","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}