{"product_id":"general-electric-ds200shvmg1aed-high-voltage-m-frame-interface-board","title":"General Electric DS200SHVMG1AED High Voltage M-Frame Interface Board","description":"\u003cp\u003eConfigured for power conversion and signal interfacing in Mark V control systems, the \u003cstrong\u003eGeneral Electric DS200SHVMG1AED\u003c\/strong\u003e (\u003cstrong\u003eDS200SHVMG1AED\u003c\/strong\u003e High Voltage M-Frame Interface Board) provides direct physical and electrical execution of high-voltage signal management within turbine drive architectures.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDS200\u003c\/strong\u003e: Indicates the Mark V Speedtronic assembly series.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSHVM\u003c\/strong\u003e: Designates the High Voltage M-Frame interface configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eG1\u003c\/strong\u003e: Specifies the primary hardware generation level.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAED\u003c\/strong\u003e: Defines the specific functional iteration and revision of the board layout.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDS200SHVMG1AED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Mark V PCB assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDependent on backplane bus loading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eM-Frame Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus and Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGeneral Electric DS200SHVMG1AED\u003c\/strong\u003e operates as an integrated component within the M-Frame drive architecture, requiring deterministic backplane bus communication velocity to maintain real-time signal processing. Firmware flash compatibility is governed by the Mark V controller master revision; users must ensure the host rack backplane supports the G1 hardware iteration before commissioning. The module manages I\/O density scaling by providing high-voltage isolation paths, ensuring that feedback signals are normalized before transmission to the main controller logic, thus protecting sensitive circuits from voltage transients.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Can this M-Frame board be hot-swapped during system operation?\u003c\/p\u003e\n\u003cp\u003eA: No. Mark V power interface boards do not support hot-swapping. The rack must be de-energized and verified for zero energy before installation or removal to prevent damage to the backplane connectors.\u003c\/p\u003e\n\u003cp\u003eQ: How is the high-voltage signal integrity maintained on the interface board?\u003c\/p\u003e\n\u003cp\u003eA: The board utilizes precision isolation components and layout spacing designed to suppress electrical noise and manage high-voltage potential across the input and output interface stages.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePreparation\u003c\/strong\u003e: Isolate the drive cabinet from all power sources. Verify that the M-Frame interface slot is clear of debris.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting\u003c\/strong\u003e: Align the PCB edges with the rack chassis card guides. Ensure the module is seated fully into the backplane connectors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnectivity\u003c\/strong\u003e: Confirm that all interface plugs and ribbon cables are secured, ensuring locking mechanisms are engaged to prevent intermittent signal loss from mechanical vibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding\u003c\/strong\u003e: Secure the board faceplate to the rack frame using the provided mounting screws to ensure proper chassis grounding and electromagnetic shielding.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerification\u003c\/strong\u003e: After installation, perform a visual inspection of the connections. Energize the system and monitor diagnostic indicators to confirm the interface board is initialized and communicating with the control processor.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52570154238264,"sku":"DS200SHVMG1AED","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/DS200SHVMG1AED1.jpg?v=1782459409","url":"https:\/\/www.automodulexpert.com\/products\/general-electric-ds200shvmg1aed-high-voltage-m-frame-interface-board","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}