{"product_id":"general-electric-ds200tcebg1baa-mark-v-termination-expander-board","title":"General Electric DS200TCEBG1BAA Mark V Termination Expander Board","description":"\u003cp\u003eThe \u003cstrong\u003eGeneral Electric DS200TCEBG1BAA\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eDS200TCEBG1BAA\u003c\/strong\u003e Termination Expander Board, serves as the primary \u003cstrong\u003eDS200TCEBG1BAA\u003c\/strong\u003e Termination Board utilized to execute signal path expansion across Speedtronic Mark V control platforms.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDS200\u003c\/strong\u003e: Standard Mark V series hardware architecture identifier.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTCEB\u003c\/strong\u003e: Termination Expander Board circuit architecture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eG1BAA\u003c\/strong\u003e: Revision identifier; indicates the initial hardware design iteration for signal routing capacity and terminal block layout.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDS200TCEBG1BAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.22 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e38 cm x 21.5 cm x 4.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive signal routing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Type\u003c\/td\u003e\n\u003ctd\u003eTerminal block signal expansion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Capacity\u003c\/td\u003e\n\u003ctd\u003eStandard Mark V I\/O mapping\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe DS200TCEBG1BAA functions as a physical interface expansion for the Mark V control system, enabling the consolidation of multiple field sensor inputs. The board facilitates channel-to-channel isolation by providing discrete signal routing paths, which is necessary to maintain signal integrity and prevent potential ground loops in complex turbine sensing arrays. This architectural approach ensures that field signals are correctly buffered and distributed to the main control core, minimizing noise interference and supporting precise data acquisition across the expander interface.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the DS200TCEBG1BAA require configuration or firmware?\u003c\/p\u003e\n\u003cp\u003eA: No. This is a passive hardware component responsible for signal routing and terminal expansion. It does not contain active processing logic or firmware, and its function is entirely determined by the wiring configuration and the connected I\/O board.\u003c\/p\u003e\n\u003cp\u003eQ: How can I verify that the board is correctly passing signals?\u003c\/p\u003e\n\u003cp\u003eA: Verification should be performed by measuring continuity from the field terminal blocks to the corresponding pins on the main controller interface connector. Ensure that no signal shorts or open circuits exist prior to commissioning the turbine loop.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the DS200TCEBG1BAA in the designated cabinet location, ensuring all mounting hardware is tightened to provide a secure chassis ground.\u003c\/li\u003e\n\u003cli\u003eRoute field wiring neatly through the cabinet wireways to prevent physical strain on the terminal expander connectors.\u003c\/li\u003e\n\u003cli\u003eTerminate all sensor leads according to the site-specific connection diagrams, observing standard practices for signal shielding and grounding.\u003c\/li\u003e\n\u003cli\u003eInspect the expander board for any loose debris or oxidation on the terminals before finalizing the connection of the I\/O ribbon cables.\u003c\/li\u003e\n\u003cli\u003eConfirm that all cable connections are fully seated, as intermittent contact at the expansion interface can lead to erroneous sensor data in the turbine control logic.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52566459679032,"sku":"DS200TCEBG1BAA","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/DS200TCEBG1BAA.jpg?v=1782372137","url":"https:\/\/www.automodulexpert.com\/products\/general-electric-ds200tcebg1baa-mark-v-termination-expander-board","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}