{"product_id":"general-electric-ds3800nmec1k1k-exciter-control-board","title":"General Electric DS3800NMEC1K1K Exciter Control Board","description":"\u003cp\u003eThe \u003cstrong\u003eGeneral Electric DS3800NMEC1K1K\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eDS3800NMEC1K1K\u003c\/strong\u003e Exciter Control Board, operates as a dedicated hardware component for field excitation management and regulation within industrial turbine control platforms.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDS3800\u003c\/strong\u003e: Designates the GE industrial control instrumentation series.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNMEC\u003c\/strong\u003e: Specifies the excitation control functional designation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1K\u003c\/strong\u003e: Denotes the hardware generation or revision level.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1K\u003c\/strong\u003e: Defines the specific technical iteration and board layout version.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDS3800NMEC1K1K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e28.8 cm x 7.2 cm x 3.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDependent on excitation load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eExciter Control Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus and Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGeneral Electric DS3800NMEC1K1K\u003c\/strong\u003e facilitates deterministic regulation of the exciter field current. It requires precise backplane bus communication velocity to maintain stability in voltage delivery to the excitation system. Firmware flash compatibility is managed via the host controller interface; technicians must confirm the host backplane supports the 1K hardware revision before deployment. The board is designed to interface directly with the excitation control rack, ensuring that field feedback signals are processed and control outputs are adjusted without latency or signal degradation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Can this exciter control board be hot-swapped while the system is under load?\u003c\/p\u003e\n\u003cp\u003eA: No. Hot-swapping is not supported. The exciter control rack power must be fully isolated before installing or removing the board to prevent electrical transient damage to the backplane pins and board components.\u003c\/p\u003e\n\u003cp\u003eQ: How is the physical connection to the backplane maintained?\u003c\/p\u003e\n\u003cp\u003eA: The board utilizes high-density backplane connectors that provide a secure mechanical and electrical interface, ensuring consistent continuity for sensitive excitation control signals.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePreparation\u003c\/strong\u003e: Ensure the exciter control rack is completely de-energized. Use an anti-static wrist strap to protect the module from electrostatic discharge.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting\u003c\/strong\u003e: Align the \u003cstrong\u003eDS3800NMEC1K1K\u003c\/strong\u003e with the rack guide rails. Ensure the unit is seated firmly so the backplane connectors are fully engaged.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Fastening\u003c\/strong\u003e: Secure the module faceplate to the rack chassis using the integrated screws to ensure structural integrity and proper electrical continuity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerification\u003c\/strong\u003e: After installation, perform a final check of all backplane connections. Energize the system and observe the diagnostic LEDs to confirm the module is initialized and regulating the exciter output as programmed.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52570347045176,"sku":"DS3800NMEC1K1K","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/DS3800NMEC1K1K.jpg?v=1782459430","url":"https:\/\/www.automodulexpert.com\/products\/general-electric-ds3800nmec1k1k-exciter-control-board","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}