This IC660BBR100 Genius I/O Relay Output Block was manufactured by GE FANUC, In Stock, 100% Guaranteed Brand New and Authentic. Link to More Information

 
Manufacturer:
GE FANUC
Part Number:
IC660BBR100
Country of Origin:
USA
Condition:
New With Original Package
Shipping Port:
ShangHai, Xiamen
Warranty:
12 Months
Collections:
 

The General Electric IC660BBR100, also cataloged as the IC660BBR100 Relay Output Block, operates as a dedicated hardware component for executing 16-point normally closed (NC) discrete output control within Genius I/O network architectures.

Hardware Specifications

Parameter Specification
Model IC660BBR100
Brand General Electric
Origin USA
Weight 1.7 kg
Dimensions 8.7 cm x 10.2 cm x 22.5 cm
Operating Temp Standard Industrial Grade
Power Consumption System-dependent
Output Type 16-Point Normally Closed Relay

Genius I/O Network Communication

The IC660BBR100 is engineered for seamless data exchange across Genius I/O serial buses. In complex control environments, the module's ability to maintain deterministic network timing is governed by the bus baud rate and the configured I/O scan settings. Firmware flash compatibility is required to ensure the module adheres to the latest communication protocols for diagnostic reporting and block-transfer functionality. Proper I/O density scaling within the rack is managed via the module's internal logic, which receives output state commands from the host PLC or controller over the serial link, ensuring reliable relay state control.

Frequently Asked Questions

Q: Does the normally closed relay state persist during a loss of Genius bus communication?

A: Upon a loss of network communication, the module default state depends on the configured failsafe parameters. The normally closed relay will remain closed unless the module logic is explicitly commanded to open by the host controller or enters a predefined fault state.

Q: Can this module be configured for diagnostics via the host PLC?

A: Yes, the module supports diagnostic reporting, including relay health monitoring and communication fault status, which can be monitored directly by the host controller's logic program.

Q: Is this module field-replaceable while the network is powered?

A: Replacing the module requires stopping the bus communications to prevent data corruption. Always verify the status of the network nodes before attempting to disconnect or replace the I/O block.

Field Installation Guidelines

  • Mounting: Secure the block to the designated mounting surface. Ensure that the module is correctly aligned with the Genius I/O connectors to maintain reliable serial link connectivity.
  • Network Wiring: Use specified shielded twisted-pair cabling for the Genius I/O serial link. Proper termination resistors must be installed at both ends of the bus to maintain signal impedance and minimize reflections.
  • Grounding and Shielding: Terminate the shield of the network cable to the designated grounding lug on the block. Maintain physical separation between output load wiring and sensitive communication cables to mitigate electromagnetic interference.
  • Thermal Management: Given the module's dimensions and relay density, ensure adequate clearance for heat dissipation within the control cabinet to maintain operational longevity.
Quick Quotes Receive price & availability FAST from our dedicated customer service team.
Delivery Expedited, Freight, And International Shipping Available.
Condition 100% New with Original Package
Payment We accept American Express, Discover, MasterCard, PayPal, and Visa. Our site is secured by RapidSSL.
Shipping Port ShangHai, Xiamen
Warranty 12 Months
Q: Is Our Pricing Competitive?
A: Yes, we collaborate with over 50 countries worldwide. As a top supplier in China, we offer significant discounts based on market trends.
Q: What Is the Warranty Period?
A: All our new and original products come with a standard one-year warranty.
Q: What Payment Methods Do We Accept?
A: We require 100% T/T (Telegraphic Transfer) payment before shipping. For items with a lead time, a 30% deposit is needed upfront, and the remaining 70% is due before shipping. If you have a representative in China, you can arrange an RMB transfer through them.
Q: What Shipping Methods Do We Use?
A: We primarily use FedEx, DHL, UPS, and BRE for shipping. If you have an account with any of these carriers, you can handle shipping directly. We also offer free shipping to China-based freight forwarders.
Q: What Is Our Delivery Time?
A: Delivery usually takes 1-3 days after receiving the initial payment. For items with a lead time, shipping will occur according to the specified schedule.
Q: How Do We Package the Goods?
A: We ensure safe packaging with multiple layers of protection. Products are first placed in their original boxes and sealed with labels. A layer of bubble wrap is then added for collision protection during transit. Finally, the items are packed securely in durable boxes.
Q: How Can Customers Contact Us and Request a Quote?
A: You can reach out to us via email, WhatsApp, WeChat, Skype, or your preferred communication platform. Contact us with your needs, and we'll provide a prompt, customized quote.
 

Recently Viewed

Express Shipping icon
Express Shipping
Rapid delivery for your urgent requirements.
Large stock icon
Extensive Inventory
Large stock for immediate dispatch.
Quality Assurance Icon
Quality Assurance
Authentic, top-grade PLC & DCS components.
Global Service icon
Global Service
Supporting clients worldwide with dependable service.