{"product_id":"general-electric-is200acleh1a-ex2100-application-control-layer-module","title":"General Electric IS200ACLEH1A EX2100 Application Control Layer Module","description":"\u003cp\u003eThe \u003cstrong\u003eGeneral Electric IS200ACLEH1A\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIS200ACLEH1A\u003c\/strong\u003e Application Control Layer Module, serves as the primary \u003cstrong\u003eIS200ACLEH1A\u003c\/strong\u003e Application Control Layer Module utilized to execute high-level control logic and excitation regulation across EX2100 platforms.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIS200\u003c\/strong\u003e: Standard hardware series designation for GE excitation control components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eACLE\u003c\/strong\u003e: Application Control Layer Engineering module architecture identifier.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eH1A\u003c\/strong\u003e: Revision sequence indicating the hardware design iteration and onboard processor configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200ACLEH1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.90 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard EX2100 control rack form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNominal 24 VDC control power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eApplication Control Layer Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eEX2100 Excitation Control Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe IS200ACLEH1A manages the application-level execution of excitation control algorithms. It utilizes high-speed internal bus architectures to interface with the regulator and bridge processors, ensuring deterministic performance for critical control loops. The module supports firmware flash compatibility, allowing for seamless updates to the control software without hardware modification. Through its advanced processing capabilities, the module maintains strict backplane bus communication velocity, ensuring that feedback loops from the generator exciter are processed with the timing precision required for stable voltage regulation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the IS200ACLEH1A require a specific firmware version for operation?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The module must be loaded with the specific firmware version compatible with the installed EX2100 system configuration to ensure proper I\/O mapping and control logic execution.\u003c\/p\u003e\n\u003cp\u003eQ: Is this module hot-swappable in an active EX2100 rack?\u003c\/p\u003e\n\u003cp\u003eA: No. Due to the module's critical role in managing excitation control logic, the EX2100 cabinet must be in a non-critical state or the specific control rack must be powered down before attempting to remove or install the module.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the control cabinet is de-energized and appropriate electrostatic discharge (ESD) precautions are taken before handling the module.\u003c\/li\u003e\n\u003cli\u003eAlign the module with the card guide rails and slide it into the designated slot in the EX2100 rack.\u003c\/li\u003e\n\u003cli\u003eEnsure the module is fully seated until the backplane connector is firmly engaged.\u003c\/li\u003e\n\u003cli\u003eSecure the module front panel using the integrated captive screws to maintain mechanical stability and ground continuity.\u003c\/li\u003e\n\u003cli\u003eVerify communication status via the onboard LED diagnostics after power-up to confirm the module has established a link with the system master controller.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52566323495224,"sku":"IS200ACLEH1A","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IS200ACLEH1A1.jpg?v=1782372137","url":"https:\/\/www.automodulexpert.com\/products\/general-electric-is200acleh1a-ex2100-application-control-layer-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}