{"product_id":"general-electric-is200aepgg1a-mark-vi-board-assembly-aepg-module","title":"General Electric IS200AEPGG1A Mark VI Board Assembly AEPG Module","description":"\u003cp\u003eConfigured for high-density I\/O processing and signal management in Mark VI platforms, the \u003cstrong\u003eGeneral Electric IS200AEPGG1A\u003c\/strong\u003e (\u003cstrong\u003eIS200AEPGG1A\u003c\/strong\u003e Board Assembly) provides direct physical\/electrical execution of complex control logic and communication tasks.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIS200\u003c\/strong\u003e: Standard hardware series designation for GE Mark VI control components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAEPG\u003c\/strong\u003e: Analog Electronic Processor Gateway circuit architecture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eG1A\u003c\/strong\u003e: Revision identifier; indicates the primary hardware iteration for the AEPG module interface.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200AEPGG1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.44 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e15.8 cm x 11.5 cm x 2.1 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5.8 W at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e16 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Outputs\u003c\/td\u003e\n\u003ctd\u003e8 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003e200 MHz ARM Cortex-M4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe IS200AEPGG1A integrates into the Mark VI control environment to manage analog front-end data acquisition and deterministic communication tasks. Utilizing the 200 MHz ARM Cortex-M4 processor, the module maintains backplane bus communication velocity across its 4 configurable ports, supporting Modbus and Profibus protocols. The board architecture includes an onboard 3.3 V supercapacitor, providing 48-hour backup for critical volatile data. Its high-density design, featuring 156 total components, supports I\/O density scaling while ensuring firmware flash compatibility for real-time control adjustments.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the onboard 3.3 V supercapacitor be replaced if it fails to hold a charge?\u003c\/p\u003e\n\u003cp\u003eA: The supercapacitor is a soldered surface-mount component integral to the PCB assembly. It is not intended for field replacement; if the 48-hour backup capability is lost, the entire board assembly must be inspected or replaced.\u003c\/p\u003e\n\u003cp\u003eQ: How should I manage the 2.6 A inrush current during startup?\u003c\/p\u003e\n\u003cp\u003eA: Ensure that the 24 VDC power supply used in the control cabinet is rated to accommodate the specified inrush current to prevent voltage sagging and potential communication timeouts during the power-on sequence.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the control cabinet is de-energized and grounded before handling the IS200AEPGG1A to mitigate electrostatic discharge risks.\u003c\/li\u003e\n\u003cli\u003eSecure the board assembly using the designated mounting points, ensuring the PCB is not flexed during installation.\u003c\/li\u003e\n\u003cli\u003eTerminate analog and digital signal cables using shielded wiring to minimize noise ingress into the 16 analog input channels.\u003c\/li\u003e\n\u003cli\u003eVerify communication port settings via the engineering workstation to align with site-specific Modbus or Profibus network topography.\u003c\/li\u003e\n\u003cli\u003eCheck all connection points for mechanical integrity post-installation to prevent intermittent signal drops caused by vibration.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52566377595192,"sku":"IS200AEPGG1A","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IS200AEPGG1A2.jpg?v=1782372136","url":"https:\/\/www.automodulexpert.com\/products\/general-electric-is200aepgg1a-mark-vi-board-assembly-aepg-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}