{"product_id":"general-electric-is200examg1aab-mark-vie-exciter-attenuator-module","title":"General Electric IS200EXAMG1AAB Mark VIe Exciter Attenuator Module","description":"\u003cp\u003eThe \u003cstrong\u003eGeneral Electric IS200EXAMG1AAB\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIS200EXAMG1AAB\u003c\/strong\u003e Exciter Attenuator Module, operates as a dedicated hardware component for high-voltage signal attenuation within EX2100 and Mark VIe excitation control platforms.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIS200\u003c\/strong\u003e: Standard hardware series designation for GE excitation control components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEXAM\u003c\/strong\u003e: Exciter Attenuator Module circuit architecture identifier.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eG1AAB\u003c\/strong\u003e: Revision sequence indicating the board design iteration and component layout for signal scaling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200EXAMG1AAB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.46 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e23 cm x 19.1 cm x 3 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNominal excitation control voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eExciter feedback signal attenuation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eEX2100 \/ Mark VIe control platforms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity Licences\u003c\/h3\u003e\n\u003cp\u003eThe IS200EXAMG1AAB functions as a critical interface for scaling high-magnitude excitation voltages into levels suitable for controller processing. By providing precise signal attenuation, the module preserves the integrity of data transmitted across deterministic network platforms. The hardware supports firmware flash compatibility, allowing for synchronized operation with the main controller's I\/O processing cycles. This module ensures that I\/O density scaling requirements are met within the cabinet, facilitating high-velocity communication and maintaining signal fidelity required for accurate generator field control.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the primary function of the IS200EXAMG1AAB in an excitation system? A: This module attenuates high-voltage feedback from the generator field to protect the downstream controller inputs and ensure that the measured voltage levels are within the dynamic range of the A\/D converters.\u003c\/p\u003e\n\u003cp\u003eQ: Is this module capable of field configuration via jumpers? A: The configuration of this module is largely hardware-fixed to maintain precision in voltage scaling; field adjustments should only be performed in accordance with the specific excitation control system documentation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the excitation system power is disconnected and the field is de-energized before beginning installation.\u003c\/li\u003e\n\u003cli\u003eMount the module within the designated excitation control cabinet slot, ensuring the backplane connector is fully seated to maintain reliable signal contact.\u003c\/li\u003e\n\u003cli\u003eTighten all mounting hardware to ensure secure mechanical grounding to the cabinet chassis.\u003c\/li\u003e\n\u003cli\u003eVerify that all signal wiring connected to the module is shielded to prevent induced noise from compromising the attenuated feedback signals.\u003c\/li\u003e\n\u003cli\u003ePerform a system verification test to compare the attenuated output against the actual field voltage, ensuring the scaling factor remains within specified tolerances.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52566305964344,"sku":"IS200EXAMG1AAB","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IS200EXAMG1AAB1.jpg?v=1782372137","url":"https:\/\/www.automodulexpert.com\/products\/general-electric-is200examg1aab-mark-vie-exciter-attenuator-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}