{"product_id":"general-electric-is200trtdh1dcb-mark-vie-rtd-input-terminal-board","title":"General Electric IS200TRTDH1DCB Mark VIe RTD Input Terminal Board","description":"\u003cp\u003eThe \u003cstrong\u003eGeneral Electric IS200TRTDH1DCB\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIS200TRTDH1DCB\u003c\/strong\u003e RTD Input Terminal Board, serves as the primary \u003cstrong\u003eIS200TRTDH1DCB\u003c\/strong\u003e Termination Board utilized to execute precision temperature signal routing across Mark VIe platforms.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIS200\u003c\/strong\u003e: Standard hardware series designation for GE Mark VIe control components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTRTD\u003c\/strong\u003e: RTD (Resistance Temperature Detector) Input terminal board circuit architecture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eH1DCB\u003c\/strong\u003e: Revision level DCB; indicates the terminal configuration and high-frequency suppression baseline for 16-channel processing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200TRTDH1DCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e100 mm x 50 mm x 25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16 (3-wire RTD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e0-10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Lead Resistance\u003c\/td\u003e\n\u003ctd\u003e15 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol\u003c\/h3\u003e\n\u003cp\u003eThe IS200TRTDH1DCB facilitates high-precision signal acquisition for critical process temperature monitoring. While primarily configured for RTD sensing, the board architecture supports integration with standard control loops, maintaining signal integrity through integrated high-frequency and surge suppression circuits. The design provides channel-to-channel isolation, minimizing the impact of thermal measurement noise within high-interference industrial zones. This setup ensures that temperature data remains consistent with 4-20 mA HART loop protocol standards during transmission to the controller, maintaining fidelity for downstream diagnostics.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does this board support 2-wire RTD configurations?\u003c\/p\u003e\n\u003cp\u003eA: The board is optimized for 3-wire RTD inputs to facilitate lead resistance compensation. If a 2-wire sensor must be used, a jumper must be installed at the terminal block to bridge the remaining connections, though accuracy will be dependent on the lead resistance.\u003c\/p\u003e\n\u003cp\u003eQ: Is the 15 ohm lead resistance limit absolute?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The 15 ohm limit is critical to maintain the accuracy of the RTD measurement. Exceeding this resistance will introduce significant measurement bias, necessitating shorter cable runs or larger gauge wiring to ensure valid input data.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the board using the designated panel-mounting holes, ensuring the chassis is grounded to the cabinet's protective earth.\u003c\/li\u003e\n\u003cli\u003eTerminate all 3-wire RTD leads directly to the board terminal blocks, ensuring that the lead resistance for each leg is balanced.\u003c\/li\u003e\n\u003cli\u003eRoute sensor cabling through dedicated conduits away from high-voltage AC lines to prevent induced noise on the sensitive RTD signals.\u003c\/li\u003e\n\u003cli\u003eVerify all wiring against the site-specific termination schedule to prevent incorrect I\/O channel mapping.\u003c\/li\u003e\n\u003cli\u003eInspect surge suppression grounding connections post-installation to ensure effective protection against industrial transients.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52566408167736,"sku":"IS200TRTDH1DCB","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IS200TRTDH1CI1.jpg?v=1782287366","url":"https:\/\/www.automodulexpert.com\/products\/general-electric-is200trtdh1dcb-mark-vie-rtd-input-terminal-board","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}