{"product_id":"general-electric-thermocouple-input-terminal-board-is200tbtch1c","title":"General Electric Thermocouple Input Terminal Board IS200TBTCH1C","description":"\u003cp\u003ehe \u003cstrong\u003eGeneral Electric IS200TBTCH1C\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIS200TBTCH1CBB\u003c\/strong\u003e Thermocouple Input Terminal Board, operates as a dedicated hardware component for temperature sensor signal termination within Mark VIe turbine control platforms.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIS200TBTCH1C\u003c\/strong\u003e: Primary terminal board base identifier for thermocouple input signal routing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIS200TBTCH1CBB\u003c\/strong\u003e: Specific assembly iteration featuring modified terminal block interface and improved signal shielding for enhanced measurement precision in thermal control loops.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200TBTCH1C \/ IS200TBTCH1CBB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e10.8 cm x 23.8 cm x 19.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive (Loop Powered)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eDIN-rail \/ Panel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Input\u003c\/td\u003e\n\u003ctd\u003eThermocouple (J, K, T, E, R, S, B, N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe IS200TBTCH1C facilitates the deterministic transmission of raw millivolt signals from field-installed thermocouples to the control system I\/O processor. The board incorporates localized cold junction compensation (CJC) points, ensuring that temperature readings are accurately referenced before being converted into digital data for the control network. This precise thermal signal acquisition is necessary for turbine regulation, as it maintains the fidelity required for real-time monitoring and protection loops within the deterministic control architecture.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the terminal board require an external power supply to operate?\u003c\/p\u003e\n\u003cp\u003eA: No. The IS200TBTCH1C is a passive termination component. The necessary voltage and reference currents for thermocouple signal conditioning are provided by the I\/O pack connected to the back of the terminal board.\u003c\/p\u003e\n\u003cp\u003eQ: Is the IS200TBTCH1C compatible with all standard thermocouple types?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The board serves as the physical interface; the specific thermocouple type compatibility (e.g., K, J, T) is determined by the configuration settings of the associated I\/O pack within the Mark VIe software.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the control cabinet is isolated from power to prevent electrical hazards during installation.\u003c\/li\u003e\n\u003cli\u003eAlign the terminal board with the mounting rails or stand-offs and secure it firmly to ensure a solid electrical ground connection.\u003c\/li\u003e\n\u003cli\u003eTerminate thermocouple wires directly to the screw terminals. Use the correct thermocouple extension wire material to avoid introducing additional junctions that could degrade accuracy.\u003c\/li\u003e\n\u003cli\u003eRoute signal wires away from high-voltage AC cables to minimize electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eVerify signal integrity by checking the millivolt output at the terminal block before locking the signal into the control loop.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52462692532536,"sku":"IS200TBTCH1CBB IS200TBTCH1C","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IS200TBTCH1CBB_1.jpg?v=1730799860","url":"https:\/\/www.automodulexpert.com\/products\/general-electric-thermocouple-input-terminal-board-is200tbtch1c","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}