{"product_id":"general-electric-ur-8nh-ct-vt-module","title":"General Electric UR 8NH CT\/VT Module","description":"\u003cp\u003eThe \u003cstrong\u003eGeneral Electric UR 8NH\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e8NH\u003c\/strong\u003e CT\/VT module, operates as a dedicated hardware component for high-precision current and voltage signal acquisition within Multilin Universal Relay (UR) platforms. This module functions as the primary interface for processing secondary-level analog inputs, providing the necessary signal isolation and scaling required for protective relaying algorithms and system monitoring.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eUR 8NH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e28 cm x 21.4 cm x 1.7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial standard environment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive signal scaling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eCT\/VT Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eMultilin Universal Relay (UR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication and Signal Conditioning\u003c\/h3\u003e\n\u003cp\u003eThe UR 8NH module integrates with the relay backplane bus to facilitate real-time data transmission of digitized current and voltage vectors to the central processor. The module architecture ensures high-fidelity signal conditioning, minimizing harmonic distortion during the conversion of field-applied primary signals to relay-readable secondary levels. Firmware flash compatibility is managed through the host relay system; technical personnel must verify that the UR chassis software version supports the 8NH signal mapping to ensure accurate protective trip timing and measurement accuracy.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the UR 8NH provide galvanic isolation for CT and VT inputs?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The module includes integrated magnetic coupling to provide galvanic isolation between the field-side secondary inputs and the internal relay circuitry, protecting the sensitive processor core from transient surges on the signal lines.\u003c\/p\u003e\n\u003cp\u003eQ: Can the module be serviced while the primary circuit is energized?\u003c\/p\u003e\n\u003cp\u003eA: No. Any intervention requires the isolation of the primary circuit and the physical short-circuiting of all current transformer (CT) secondary loops at the external terminal blocks. Attempting to remove the module with active CT current will generate lethal voltages across the terminals and damage the module connectors.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eConfirm that all primary power sources are isolated and CT secondary circuits are securely shorted.\u003c\/li\u003e\n\u003cli\u003eEnsure the UR chassis is de-energized to prevent electrical faults during module insertion.\u003c\/li\u003e\n\u003cli\u003eAlign the module with the dedicated slot guides, ensuring the backplane pins are not subjected to mechanical force.\u003c\/li\u003e\n\u003cli\u003eSeat the module firmly into the chassis and secure the front-panel captive mounting hardware.\u003c\/li\u003e\n\u003cli\u003eTerminate CT and VT wiring to the rear blocks, verifying that wire gauges are compatible with the terminal ratings.\u003c\/li\u003e\n\u003cli\u003ePerform an injection test using a secondary test set to verify the accuracy of the signal ratios before transitioning the relay to operational service.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52620200476984,"sku":"UR 8NH","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/UR8NH1.jpg?v=1783497528","url":"https:\/\/www.automodulexpert.com\/products\/general-electric-ur-8nh-ct-vt-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}