{"product_id":"hart-analog-input-module-aai143-h00-a4s00-yokogawa","title":"HART Analog Input Module AAI143-H00\/A4S00 Yokogawa","description":"\u003ch2 data-start=\"166\" data-end=\"190\"\u003eProduct Description\u003c\/h2\u003e\n\u003cp data-start=\"191\" data-end=\"575\"\u003eThe \u003cstrong data-start=\"195\" data-end=\"215\"\u003eAAI143-H00\/A4S00\u003c\/strong\u003e is a \u003cstrong data-start=\"221\" data-end=\"268\"\u003e16-channel high-density analog input module\u003c\/strong\u003e designed for \u003cstrong data-start=\"282\" data-end=\"332\"\u003eYokogawa CENTUM VP and CS 3000 control systems\u003c\/strong\u003e. It interfaces with \u003cstrong data-start=\"353\" data-end=\"375\"\u003e4–20 mA DC signals\u003c\/strong\u003e from field transmitters and features \u003cstrong data-start=\"413\" data-end=\"443\"\u003eHART digital communication\u003c\/strong\u003e, enabling the control system to access diagnostics and maintenance data from intelligent instruments without additional hardware.\u003c\/p\u003e\n\u003cp data-start=\"577\" data-end=\"1063\"\u003eThis variant includes the \u003cstrong data-start=\"603\" data-end=\"620\"\u003e\/A4S00 option\u003c\/strong\u003e, which provides a \u003cstrong data-start=\"639\" data-end=\"699\"\u003efactory-installed ATA4S-00 Pressure Clamp Terminal Block\u003c\/strong\u003e for secure, direct field wiring without specialized connector cables. Each channel is configurable via \u003cstrong data-start=\"803\" data-end=\"820\"\u003einternal pins\u003c\/strong\u003e to support either \u003cstrong data-start=\"839\" data-end=\"864\"\u003e2-wire (loop-powered)\u003c\/strong\u003e or \u003cstrong data-start=\"868\" data-end=\"893\"\u003e4-wire (self-powered)\u003c\/strong\u003e transmitters. With \u003cstrong data-start=\"913\" data-end=\"936\"\u003e1500 V AC isolation\u003c\/strong\u003e and low thermal drift, the module ensures \u003cstrong data-start=\"979\" data-end=\"1023\"\u003eaccurate and reliable signal acquisition\u003c\/strong\u003e in demanding industrial environments.\u003c\/p\u003e\n\u003chr data-start=\"1065\" data-end=\"1068\"\u003e\n\u003ch2 data-start=\"1070\" data-end=\"1099\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1101\" data-end=\"1806\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1101\" data-end=\"1130\"\u003e\n\u003ctr data-start=\"1101\" data-end=\"1130\"\u003e\n\u003cth data-start=\"1101\" data-end=\"1113\" data-col-size=\"sm\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"1113\" data-end=\"1130\" data-col-size=\"md\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1161\" data-end=\"1806\"\u003e\n\u003ctr data-start=\"1161\" data-end=\"1218\"\u003e\n\u003ctd data-start=\"1161\" data-end=\"1178\" data-col-size=\"sm\"\u003eInput Channels\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1178\" data-end=\"1218\"\u003e16, fully isolated from system logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1219\" data-end=\"1248\"\u003e\n\u003ctd data-start=\"1219\" data-end=\"1234\" data-col-size=\"sm\"\u003eSignal Range\u003c\/td\u003e\n\u003ctd data-start=\"1234\" data-end=\"1248\" data-col-size=\"md\"\u003e4–20 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1249\" data-end=\"1312\"\u003e\n\u003ctd data-start=\"1249\" data-end=\"1273\" data-col-size=\"sm\"\u003eDigital Communication\u003c\/td\u003e\n\u003ctd data-start=\"1273\" data-end=\"1312\" data-col-size=\"md\"\u003eHART Protocol (digital over analog)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1313\" data-end=\"1378\"\u003e\n\u003ctd data-start=\"1313\" data-end=\"1334\" data-col-size=\"sm\"\u003eTerminal Interface\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1334\" data-end=\"1378\"\u003ePressure Clamp Terminal Block (ATA4S-00)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1379\" data-end=\"1412\"\u003e\n\u003ctd data-start=\"1379\" data-end=\"1402\" data-col-size=\"sm\"\u003eMeasurement Accuracy\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1402\" data-end=\"1412\"\u003e±16 µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1413\" data-end=\"1442\"\u003e\n\u003ctd data-start=\"1413\" data-end=\"1433\" data-col-size=\"sm\"\u003eData Update Cycle\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1433\" data-end=\"1442\"\u003e10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1443\" data-end=\"1500\"\u003e\n\u003ctd data-start=\"1443\" data-end=\"1463\" data-col-size=\"sm\"\u003eTransmitter Power\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1463\" data-end=\"1500\"\u003e≥19.0 V at 20 mA; ≤25.5 V at 0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1501\" data-end=\"1552\"\u003e\n\u003ctd data-start=\"1501\" data-end=\"1520\" data-col-size=\"sm\"\u003eInput Resistance\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1520\" data-end=\"1552\"\u003e270 Ω (20 mA) – 350 Ω (4 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1553\" data-end=\"1610\"\u003e\n\u003ctd data-start=\"1553\" data-end=\"1573\" data-col-size=\"sm\"\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1573\" data-end=\"1610\"\u003e1500 V AC (input to system logic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1611\" data-end=\"1654\"\u003e\n\u003ctd data-start=\"1611\" data-end=\"1635\" data-col-size=\"sm\"\u003eTemperature Stability\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1635\" data-end=\"1654\"\u003e±16 µA per 10°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1655\" data-end=\"1711\"\u003e\n\u003ctd data-start=\"1655\" data-end=\"1675\" data-col-size=\"sm\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1675\" data-end=\"1711\"\u003e5 V DC: 230 mA \/ 24 V DC: 540 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1712\" data-end=\"1736\"\u003e\n\u003ctd data-start=\"1712\" data-end=\"1726\" data-col-size=\"sm\"\u003eModule Mass\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1726\" data-end=\"1736\"\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1737\" data-end=\"1806\"\u003e\n\u003ctd data-start=\"1737\" data-end=\"1751\" data-col-size=\"sm\"\u003eModule Type\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1751\" data-end=\"1806\"\u003eIsolated analog input, 2-wire \/ 4-wire configurable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"1808\" data-end=\"1811\"\u003e\n\u003ch2 data-start=\"1813\" data-end=\"1853\"\u003eField Configuration and Integration\u003c\/h2\u003e\n\u003cul data-start=\"1854\" data-end=\"2245\"\u003e\n\u003cli data-start=\"1854\" data-end=\"1928\"\u003e\n\u003cp data-start=\"1856\" data-end=\"1928\"\u003e\u003cstrong data-start=\"1856\" data-end=\"1882\"\u003eSource-capable module:\u003c\/strong\u003e Provides loop power to 2-wire transmitters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1929\" data-end=\"2059\"\u003e\n\u003cp data-start=\"1931\" data-end=\"2059\"\u003e\u003cstrong data-start=\"1931\" data-end=\"1949\"\u003eHot-swappable:\u003c\/strong\u003e Supports redundant FIO configurations to maintain \u003cstrong data-start=\"2000\" data-end=\"2030\"\u003econtinuous process control\u003c\/strong\u003e during module replacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2060\" data-end=\"2245\"\u003e\n\u003cp data-start=\"2062\" data-end=\"2245\"\u003e\u003cstrong data-start=\"2062\" data-end=\"2079\"\u003eApplications:\u003c\/strong\u003e Widely used in \u003cstrong data-start=\"2095\" data-end=\"2157\"\u003epower generation, water treatment, and chemical processing\u003c\/strong\u003e, especially where \u003cstrong data-start=\"2176\" data-end=\"2199\"\u003ehigh-speed sampling\u003c\/strong\u003e and \u003cstrong data-start=\"2204\" data-end=\"2229\"\u003eHART asset management\u003c\/strong\u003e are required.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2247\" data-end=\"2250\"\u003e\n\u003ch2 data-start=\"2252\" data-end=\"2283\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp data-start=\"2285\" data-end=\"2511\"\u003e\u003cstrong data-start=\"2285\" data-end=\"2351\"\u003eQ: Can this module support self-powered (4-wire) transmitters?\u003c\/strong\u003e\u003cbr data-start=\"2351\" data-end=\"2354\"\u003e\u003cstrong data-start=\"2354\" data-end=\"2360\"\u003eA:\u003c\/strong\u003e Yes. Each channel can be individually configured via internal pins to support either \u003cstrong data-start=\"2446\" data-end=\"2471\"\u003e2-wire (loop-powered)\u003c\/strong\u003e or \u003cstrong data-start=\"2475\" data-end=\"2500\"\u003e4-wire (self-powered)\u003c\/strong\u003e devices.\u003c\/p\u003e\n\u003cp data-start=\"2513\" data-end=\"2699\"\u003e\u003cstrong data-start=\"2513\" data-end=\"2593\"\u003eQ: What is the maximum current the module can supply to a field transmitter?\u003c\/strong\u003e\u003cbr data-start=\"2593\" data-end=\"2596\"\u003e\u003cstrong data-start=\"2596\" data-end=\"2602\"\u003eA:\u003c\/strong\u003e The \u003cstrong data-start=\"2607\" data-end=\"2635\"\u003etransmitter power supply\u003c\/strong\u003e is limited to \u003cstrong data-start=\"2650\" data-end=\"2671\"\u003e25 mA per channel\u003c\/strong\u003e to protect the circuitry.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51667135627576,"sku":"AAI143-H00\/A4S00","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/AAI143-H00-K4A00.jpg?v=1769568752","url":"https:\/\/www.automodulexpert.com\/products\/hart-analog-input-module-aai143-h00-a4s00-yokogawa","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}