This HE693RTM705 RTU Master Communication Module was manufactured by GE FANUC, In Stock, 100% Guaranteed Brand New and Authentic. Link to More Information

 
Manufacturer:
GE FANUC
Part Number:
HE693RTM705
Country of Origin:
USA
Condition:
New With Original Package
Shipping Port:
ShangHai, Xiamen
Warranty:
12 Months
Collections:
 

The GE HE693RTM705, also cataloged as the HE693RTM705 Communication Module, operates as a dedicated hardware component for Modbus RTU protocol translation and data exchange within Series 90-30 PLC system architectures.

Hardware Specifications

Parameter Specification
Model HE693RTM705
Brand GE
Origin Standard Industrial Manufacturing
Weight 2 kg
Dimensions 19 inch x 3U Rack-mount
Operating Temp 0 deg C to +60 deg C
Power Consumption Not specified
Processor PowerPC 1 GHz
Memory 512 MB to 2 GB
Storage 2 GB to 8 GB
Communication Ethernet, RS-232, RS-485
Protection Rating IP67

Profinet / EtherNet/IP Deterministic Networks

The module integrates into the control network via high-speed deterministic pathways, ensuring consistent latency for Modbus RTU polling cycles. It facilitates backplane communication by managing data packet prioritization, which prevents buffer overflow during high-traffic intervals on the fieldbus. Firmware compatibility ensures that the interface maintains synchronization with the host processor clock, providing deterministic execution of read and write commands across the physical communication ports.

Frequently Asked Questions (FAQ)

Q: Does the HE693RTM705 support hot-swapping during PLC operation?

A: The module is designed for fixed-slot integration. Hot-swapping is not recommended unless the specific PLC backplane architecture explicitly supports power-cycling isolation for the module slot to prevent bus communication errors.

Q: How should the RS-485 interface be terminated to ensure signal integrity?

A: The RS-485 port should be terminated at both ends of the transmission line using a 120 Ohm resistor. Ensure the shield is grounded at a single point to mitigate common-mode noise interference in industrial electrical environments.

Field Installation Guidelines

  1. Ensure the module is seated fully within the designated rack slot to establish positive contact with the backplane pins.
  2. Verify that the operating environment is within the rated 0 deg C to +60 deg C range; maintain adequate clearance above and below the rack for convective cooling.
  3. Use shielded twisted-pair cabling for all RS-485 runs. Keep communication cables physically separated from high-voltage AC power lines to prevent induced electromagnetic interference.
  4. For Ethernet connections, verify that the patch cables meet the required category specifications for the network throughput.
  5. Confirm the IP67-rated seals are intact if the module is installed in an environment with high humidity or particulate contamination.
Quick Quotes Receive price & availability FAST from our dedicated customer service team.
Delivery Expedited, Freight, And International Shipping Available.
Condition 100% New with Original Package
Payment We accept American Express, Discover, MasterCard, PayPal, and Visa. Our site is secured by RapidSSL.
Shipping Port ShangHai, Xiamen
Warranty 12 Months
Q: Is Our Pricing Competitive?
A: Yes, we collaborate with over 50 countries worldwide. As a top supplier in China, we offer significant discounts based on market trends.
Q: What Is the Warranty Period?
A: All our new and original products come with a standard one-year warranty.
Q: What Payment Methods Do We Accept?
A: We require 100% T/T (Telegraphic Transfer) payment before shipping. For items with a lead time, a 30% deposit is needed upfront, and the remaining 70% is due before shipping. If you have a representative in China, you can arrange an RMB transfer through them.
Q: What Shipping Methods Do We Use?
A: We primarily use FedEx, DHL, UPS, and BRE for shipping. If you have an account with any of these carriers, you can handle shipping directly. We also offer free shipping to China-based freight forwarders.
Q: What Is Our Delivery Time?
A: Delivery usually takes 1-3 days after receiving the initial payment. For items with a lead time, shipping will occur according to the specified schedule.
Q: How Do We Package the Goods?
A: We ensure safe packaging with multiple layers of protection. Products are first placed in their original boxes and sealed with labels. A layer of bubble wrap is then added for collision protection during transit. Finally, the items are packed securely in durable boxes.
Q: How Can Customers Contact Us and Request a Quote?
A: You can reach out to us via email, WhatsApp, WeChat, Skype, or your preferred communication platform. Contact us with your needs, and we'll provide a prompt, customized quote.
 

Recently Viewed

Express Shipping icon
Express Shipping
Rapid delivery for your urgent requirements.
Large stock icon
Extensive Inventory
Large stock for immediate dispatch.
Quality Assurance Icon
Quality Assurance
Authentic, top-grade PLC & DCS components.
Global Service icon
Global Service
Supporting clients worldwide with dependable service.