{"product_id":"honeywell-51305844-175-tc-llmux2-32ptmux-module","title":"Honeywell 51305844-175 TC LLMUX2 32PTMUX Module","description":"\u003ch2\u003eHoneywell 51305844-175 TC LLMUX2 Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 51305844-175\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e51305844-175\u003c\/strong\u003e Analog Input Module, operates as a dedicated hardware component for multi-channel analog signal acquisition within Honeywell TC LLMUX2 32PTMUX platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e51305844-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e2.5 x 4.5 x 1 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eStandard backplane bus powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eTC LLMUX2 32PTMUX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e32 analog input points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Types\u003c\/td\u003e\n\u003ctd\u003e0-10 VDC \/ 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\/D Conversion\u003c\/td\u003e\n\u003ctd\u003e16-bit resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eAnalog Signal Processing \u0026amp; CJC Integration\u003c\/h3\u003e\n\u003cp\u003eDesigned specifically for Honeywell DCS architectures, this module utilizes dedicated multiplexing circuits to process 32 high-density analog channels. Integrated cold junction compensation (CJC) circuits maintain measurement integrity across changing ambient temperatures during low-level voltage and 4-20 mA HART loop signal acquisition. Channel-to-channel isolation prevents ground loops and electrical interference from corrupting the 16-bit analog-to-digital conversion, allowing deterministic communication across the backplane bus.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the 51305844-175 module convert 4-20 mA current signals into digital control values?\u003c\/p\u003e\n\u003cp\u003eA: The module passes incoming analog signals through precise signal-conditioning networks before feeding them into a high-resolution 16-bit A\/D converter. The digitized values stream across the internal LLMUX2 interface bus directly into the DCS processor memory map.\u003c\/p\u003e\n\u003cp\u003eQ: What precautions prevent ground loop noise on field signal wiring across the 32 channels?\u003c\/p\u003e\n\u003cp\u003eA: You must maintain dedicated shield continuity by grounding overall cable shields at a single point on the cabinet grounding bar. Onboard isolation circuitry prevents common-mode voltage differences between channel channels from inducing measurement errors.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the board firmly into the designated rack or enclosure slot, confirming backplane bus connectors engage fully without mechanical stress. Ensure all system power is isolated prior to inserting or removing the card to prevent transient voltage spikes. Strip incoming sensor conductors cleanly and secure them into the terminal block, maintaining separate cable runs for signal cables and high-voltage AC power lines. Connect field cable shields directly to the single-point cabinet Earth ground bus to optimize noise suppression and preserve signal accuracy.\u003c\/p\u003e","brand":"HONEYWELL","offers":[{"title":"Default Title","offer_id":51283991068984,"sku":"51305844-175","price":250.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/581._bb79bf7d-6727-4622-bcce-bcfb8747d25f.jpg?v=1791439242","url":"https:\/\/www.automodulexpert.com\/products\/honeywell-51305844-175-tc-llmux2-32ptmux-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}