{"product_id":"honeywell-cc-tpox01-profibus-dp-gateway-communication-module","title":"Honeywell CC-TPOX01 Profibus DP Gateway Communication Module","description":"\u003ch2\u003eHoneywell CC-TPOX01 Profibus DP Gateway Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-TPOX01\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCC-TPOX01\u003c\/strong\u003e PROFIBUS DP Gateway Module, operates as a dedicated hardware component for PROFIBUS DP fieldbus communication within Honeywell Experion PKS distributed control systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCC-TPOX01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA \/ Global Manufacturing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard industrial module footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard industrial cabinet rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51306528-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePROFIBUS DP Gateway \/ Communication Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eExperion PKS DCS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003ePROFIBUS DP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Rate\u003c\/td\u003e\n\u003ctd\u003e9.6 kbps to 12 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Interface\u003c\/td\u003e\n\u003ctd\u003e9-pin D-sub connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eCompatible Honeywell control-system hardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfibus Network Integration and Protocol Conversion\u003c\/h3\u003e\n\u003cp\u003eThe gateway module establishes bi-directional communication between field-level PROFIBUS DP devices and the broader supervisory control architecture. By handling data exchange across transmission rates scaling up to 12 Mbps, the hardware maintains deterministic data throughput for connected motor control centers, variable-frequency drives, and remote I\/O stations. Channel isolation principles and robust 9-pin physical interfaces prevent ground loops and electromagnetic interference from corrupting telegram exchanges along the serial bus.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the CC-TPOX01 gateway module be hot-swapped in an active industrial enclosure?\u003c\/p\u003e\n\u003cp\u003eI: Power should be isolated from the specific backplane segment before inserting or removing communication hardware to prevent unmanaged bus resets or data corruption.\u003c\/p\u003e\n\u003cp\u003eQ: What physical connector standard is utilized for field-side communication links?\u003c\/p\u003e\n\u003cp\u003eA: Field connectivity relies on a standard 9-pin D-sub connector mapped to the PROFIBUS DP serial interface specifications.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the CC-TPOX01 module securely onto the designated control-system hardware rack or carrier.\u003c\/li\u003e\n\u003cli\u003eVerify that the incoming power supply measures a stable 24 VDC at the designated terminals prior to energization.\u003c\/li\u003e\n\u003cli\u003eTerminate the PROFIBUS DP shielded twisted-pair cable to the 9-pin D-sub connector, ensuring proper grounding of the cable shield at both ends where applicable.\u003c\/li\u003e\n\u003cli\u003eConfirm network termination switch settings on the first and last physical nodes of the PROFIBUS segment to prevent signal reflections.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"HONEYWELL","offers":[{"title":"Default Title","offer_id":53381463933240,"sku":"CC-TPOX01","price":250.0,"currency_code":"USD","in_stock":true}],"url":"https:\/\/www.automodulexpert.com\/products\/honeywell-cc-tpox01-profibus-dp-gateway-communication-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}