{"product_id":"honeywell-fc-tdol-0724p-safety-manager-digital-output-fta","title":"Honeywell FC-TDOL-0724P Safety Manager Digital Output FTA","description":"\u003ch2\u003eHoneywell FC-TDOL-0724P Line-Monitored Digital Output FTA\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell FC-TDOL-0724P\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eTDOL-0724P\u003c\/strong\u003e Line-Monitored Digital Output FTA, operates as a dedicated hardware component for 7-channel 24 VDC digital output execution within Honeywell Safety Manager system networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFC-TDOL-0724P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eManufacturer Standard Facility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2 kg (Shipping Weight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard DIN-rail \/ cabinet mount profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eUp to 70 deg C (fuse derating from 2 A at 25 deg C to 1.9 A at 70 deg C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC ±20% output supply voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Output Channels\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Current per Channel\u003c\/td\u003e\n\u003ctd\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-Circuit Detection Threshold\u003c\/td\u003e\n\u003ctd\u003e200 Ω \u0026lt; R_Th \u0026lt; 400 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Fuse Rating\u003c\/td\u003e\n\u003ctd\u003e2 A (5 × 20 mm, Littelfuse 0213002)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformal Coating\u003c\/td\u003e\n\u003ctd\u003eYes (FC version)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control Signal Integration and Isolation Architecture\u003c\/h3\u003e\n\u003cp\u003eThe module executes precise digital output control and line monitoring for final elements such as solenoid valves and actuators across safety instrumented systems. Channel-to-channel isolation safeguards internal controller backplanes against transient voltage spikes and inductive load kickback by utilizing integrated spark-suppression diodes. Furthermore, continuous circuit diagnostics and short-circuit detection thresholds actively supervise field wiring integrity without disrupting adjacent control loops.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the electrical rating and protection parameters for the output fuses?\u003c\/p\u003e\n\u003cp\u003eA: Each of the seven channels is protected by a 2 A fuse (5 × 20 mm dimensions, Littelfuse part number 0213002) rated for 250 VAC and 300 VDC, subject to linear derating to 1.9 A at 70 deg C.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module handle short-circuit detection on the output channels?\u003c\/p\u003e\n\u003cp\u003eA: The circuit continuously monitors field wiring, triggering fault diagnostics when load resistance falls within the specific short-circuit detection threshold of 200 Ω to 400 Ω.\u003c\/p\u003e\n\u003cp\u003eQ: What power supply voltage is required to drive the output channels?\u003c\/p\u003e\n\u003cp\u003eA: The output loops operate on a nominal 24 VDC supply voltage with a permissible tolerance range of ±20%.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure that upstream 24 VDC power distribution is fully de-energized before mounting the termination assembly or servicing channel fuses to prevent electrical arcing.\u003c\/li\u003e\n\u003cli\u003eMount the unit securely within the industrial control cabinet, ensuring proper ventilation space to accommodate ambient temperatures up to 70 deg C.\u003c\/li\u003e\n\u003cli\u003eTerminate inductive loads with appropriate spark-suppression diodes to protect switching components against high voltage transients.\u003c\/li\u003e\n\u003cli\u003eVerify that field wiring resistance complies with line monitoring thresholds and check fuse seating before initiating system loop checks.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HONEYWELL","offers":[{"title":"Default Title","offer_id":53291961483576,"sku":"FC-TDOL-0724P","price":250.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/627_0e66453e-8112-41b3-884b-189edcd01309.jpg?v=1792135607","url":"https:\/\/www.automodulexpert.com\/products\/honeywell-fc-tdol-0724p-safety-manager-digital-output-fta","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}