{"product_id":"honeywell-pub6438sr-chn-spyder-bacnet-unitary-controller","title":"Honeywell PUB6438SR-CHN Spyder BACnet Unitary Controller","description":"\u003ch2\u003eHoneywell PUB6438SR-CHN Spyder BACnet Unitary Controller\u003c\/h2\u003e\n\u003cp\u003eConfigured for direct equipment switching and modulating field control in building automation networks, the \u003cstrong\u003eHoneywell PUB6438SR-CHN\u003c\/strong\u003e (\u003cstrong\u003ePUB6438SR\u003c\/strong\u003e Programmable Unitary Controller) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePUB6438SR-CHN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e13.84 x 17.40 x 5.74 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.68 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VAC at 50\/60 Hz, 10 VA max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Protocol\u003c\/td\u003e\n\u003ctd\u003eBACnet MS\/TP over RS-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUniversal Inputs (UI)\u003c\/td\u003e\n\u003ctd\u003e6 channels (0-10 VDC, 4-20 mA, NTC 20k ohm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs (DI)\u003c\/td\u003e\n\u003ctd\u003e4 channels (dry contact closures)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs (AO)\u003c\/td\u003e\n\u003ctd\u003e3 channels (0-10 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Outputs (DO)\u003c\/td\u003e\n\u003ctd\u003e8 channels (SPST relays)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; Fieldbus Communications\u003c\/h3\u003e\n\u003cp\u003eThis module operates on an isolated RS-485 serial bus running the BACnet MS\/TP protocol, enabling high-speed fieldbus connectivity to master building controllers and DCS platforms. The internal hardware architecture incorporates dedicated channel-to-channel isolation on analog and digital terminals to prevent ground loop interference. Each universal input channel utilizes an internal precision resistor array to scale incoming 4-20 mA HART loop protocol current signals and 0-10 VDC voltage ranges directly into processing logic. Furthermore, onboard microcontroller routines execute cold junction compensation (CJC) algorithms across connected temperature sensing elements, preserving measurement linearities during ambient panel fluctuations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What power source does the controller require for internal logic and relay actuation?\u003c\/p\u003e\n\u003cp\u003eA: The device requires a nominal 24 VAC power supply at 50\/60 Hz. Connect the power wiring to the designated removable screw terminals, ensuring the total load remains under the 10 VA maximum rating.\u003c\/p\u003e\n\u003cp\u003eQ: How does the RS-485 network port handle signal reflections over long cable runs?\u003c\/p\u003e\n\u003cp\u003eA: The onboard BACnet MS\/TP transceiver operates over a shielded twisted-pair line. For bus lengths approaching maximum field limits, technician crews must terminate both end nodes of the RS-485 segment with 120 ohm end-of-line (EOL) resistors.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the controller securely on a standard 35 mm DIN rail or directly to a flat cabinet backplate using the integrated mounting feet. Wire all sensor inputs and actuator outputs using shielded twisted-pair cables to mitigate ambient electromagnetic noise. Ground the drain wire of each shield strictly at the main panel ground bar; never ground the shield at both ends, as this creates ground loops that corrupt low-voltage analog signals.\u003c\/p\u003e\n\u003cp\u003eMaintain clear physical separation between high-voltage power lines and low-voltage signal lines within the wiring ducts. Ensure technicians maintain at least 5 full NPT thread engagements on all rigid conduit connections leading into the enclosure. Before powering on the system, verify all removable terminal blocks are fully seated and measure incoming power levels to confirm supply stability within the specified operating tolerance.\u003c\/p\u003e","brand":"HONEYWELL","offers":[{"title":"Default Title","offer_id":51284307378488,"sku":"PUB6438SR-CHN","price":250.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/SIO6042.jpg?v=1761547925","url":"https:\/\/www.automodulexpert.com\/products\/honeywell-pub6438sr-chn-spyder-bacnet-unitary-controller","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}