{"product_id":"ic200alg240cadb-ge-analog-input-module-new-original-stock","title":"IC200ALG240CADB GE Analog Input Module New \u0026 Original Stock","description":"\u003cp\u003eThe \u003cstrong\u003eGE IC200ALG240CADB\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC200ALG240CADB\u003c\/strong\u003e Analog Input Module, operates as a dedicated hardware component for high-precision signal acquisition within VersaMax control network platforms. The module executes the conversion of incoming analog signals into digital values compatible with the PLC backplane architecture. It facilitates real-time process variable monitoring, ensuring deterministic data processing for industrial control loops.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eIC200ALG240CADB\u003c\/strong\u003e represents a specific configuration within the VersaMax analog module series. The \"C\" suffix typically denotes the hardware revision, while \"ADB\" indicates the specific terminal block and signal conditioning profile associated with this catalog number. The module is engineered for fixed integration within the VersaMax I\/O system, and no further user-configurable internal matrix variants exist for this unit.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200ALG240CADB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e300 x 150 x 40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial standard range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDependent on backplane loading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eAnalog voltage\/current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe IC200ALG240CADB is engineered for integration into deterministic industrial networks, ensuring that input signal throughput is synchronized with the CPU scan rate. The module supports I\/O density scaling, allowing users to expand signal acquisition capabilities across the VersaMax platform without compromising data integrity. Firmware flash compatibility allows for internal calibration updates, while the backplane bus communication velocity is optimized to ensure that digitized data packets are transmitted to the controller with minimal latency, supporting real-time process response requirements.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does this module support hot-swapping during normal system operation?\u003c\/p\u003e\n\u003cp\u003eA: The VersaMax platform supports module insertion and removal; however, users must verify that the base unit and backplane configuration are specifically rated for hot-swap operations to avoid potential electrical faults on the backplane bus.\u003c\/p\u003e\n\u003cp\u003eQ: Is external power required for the analog input loop?\u003c\/p\u003e\n\u003cp\u003eA: This depends on the specific transmitter type; the module supports standard analog configurations, but users should check the wiring diagram to determine if a 24 VDC loop power supply is required for specific current-loop field instruments.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the module securely onto the 35 mm DIN rail, ensuring the locking clip provides firm mechanical contact with the rail.\u003c\/li\u003e\n\u003cli\u003eTerminate all signal wiring using shielded cables to reduce electromagnetic interference (EMI) and common-mode noise on the analog input channels.\u003c\/li\u003e\n\u003cli\u003eConnect the cable shields to the system's common ground point at the module's dedicated grounding terminal to prevent ground loops.\u003c\/li\u003e\n\u003cli\u003eMaintain sufficient physical separation between analog input signal wires and high-voltage AC power cabling to prevent crosstalk and inductive interference.\u003c\/li\u003e\n\u003cli\u003eInspect terminal screws for correct torque levels after installation to ensure vibration resistance and stable electrical contact.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52432180576568,"sku":"IC200ALG240CADB","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IC200ALG240-EC.jpg?v=1779867874","url":"https:\/\/www.automodulexpert.com\/products\/ic200alg240cadb-ge-analog-input-module-new-original-stock","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}