{"product_id":"ic200alg260a-ge-fanuc-analog-input-module-datasheet-technical-manual","title":"IC200ALG260A GE Fanuc Analog Input Module | Datasheet \u0026 Technical Manual","description":"\u003cp\u003eConfigured for precision signal acquisition in Versamax control networks, the \u003cstrong\u003eGE Fanuc IC200ALG260A\u003c\/strong\u003e (\u003cstrong\u003eIC200ALG260A\u003c\/strong\u003e Analog Input Module) provides direct physical\/electrical execution. This hardware component translates field-side analog signals into digitized values for controller processing within the Versamax I\/O architecture.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe IC200ALG260A serves as a high-performance analog input interface. The \"A\" suffix designates the initial production release, which includes standardized internal A\/D conversion circuitry calibrated for industrial signal ranges.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200ALG260A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eRefer to device label\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.56 lbs (0.26 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Versamax module footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 VDC backplane current consumption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe IC200ALG260A incorporates internal circuitry designed to mitigate ground loop formation through channel-to-channel isolation. This electrical separation ensures that signals from varying field devices remain independent, preventing common-mode noise from propagating across the input array. Proper implementation of this feature requires that cable shields are grounded at a single, consistent reference point to maintain the integrity of the isolation boundary during high-resolution data acquisition.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the module support HART protocol communication?\u003c\/p\u003e\n\u003cp\u003eA: The IC200ALG260A is designed for standard analog signal acquisition and does not provide native support for HART digital signal overlay.\u003c\/p\u003e\n\u003cp\u003eQ: How is the A\/D conversion resolution verified during commissioning?\u003c\/p\u003e\n\u003cp\u003eA: Users should perform a loop calibration using a high-precision signal generator and compare the digitized PLC register values against the generated input signal to ensure accuracy within the specified performance tolerance.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConnect analog signal wiring using shielded, twisted-pair cables to protect low-level inputs from electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eEnsure all analog inputs are correctly configured for the signal type (e.g., 4-20 mA or voltage) in the controller software before applying field power.\u003c\/li\u003e\n\u003cli\u003eRoute analog signal cabling in dedicated cable trays, maintaining maximum separation from high-voltage AC power feeders to minimize induced noise.\u003c\/li\u003e\n\u003cli\u003eTerminate signal cable shields at a single point, ideally at the cabinet's earth ground bus, to prevent circulating currents that can interfere with input precision.\u003c\/li\u003e\n\u003cli\u003eInspect terminal contacts for secure mechanical seating to prevent high-resistance connections that could introduce signal drift.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52443242889528,"sku":"IC200ALG260A","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IC200ALG260C.jpg?v=1750411670","url":"https:\/\/www.automodulexpert.com\/products\/ic200alg260a-ge-fanuc-analog-input-module-datasheet-technical-manual","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}