{"product_id":"ic200alg260d-general-electric-analog-input-module-new-original-stock","title":"IC200ALG260D General Electric Analog Input Module New \u0026 Original Stock","description":"\u003cp\u003eConfigured for high-precision voltage and current sensing in Versamax control networks, the \u003cstrong\u003eGeneral Electric IC200ALG260D\u003c\/strong\u003e (\u003cstrong\u003eIC200ALG260D\u003c\/strong\u003e Analog Input Module) provides direct physical\/electrical execution. This module conditions incoming analog signals, performing high-resolution analog-to-digital conversion before transferring the data to the controller backplane for process logic integration.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200ALG260D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e5.1 cm x 12.7 cm x 12.7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eBackplane dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eVersamax Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe IC200ALG260D module ensures high-speed synchronization within the Versamax system by utilizing deterministic backplane communication protocols. The module architecture allows for efficient I\/O density scaling, supporting the concurrent processing of multiple input channels without introducing cycle-time degradation. When integrated into Profinet or EtherNet\/IP platforms, the module acts as a slave node, delivering signal data with strictly defined timing intervals. Compatibility with current firmware versions is managed through the central I\/O configuration utility, which validates the operational state of the analog processing circuitry during system boot-up.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the IC200ALG260D support hot-swapping while the Versamax backplane is powered?\u003c\/p\u003e\n\u003cp\u003eA: The Versamax module design is intended for hot-swap operations. However, ensure that the I\/O rack is properly grounded and the power budget allows for the current draw of the module being inserted.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum resolution capacity for analog signal conversion?\u003c\/p\u003e\n\u003cp\u003eA: This module utilizes 12-bit to 16-bit resolution architecture (depending on the specific channel configuration and range settings) to convert field analog voltages or currents into digital values for the PLC CPU.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDIN-Rail Mounting: Ensure the module is snapped securely onto the mounting rail. Verify that the interlocking mechanism is fully seated to maintain electrical contact with the backplane bus.\u003c\/li\u003e\n\u003cli\u003eShielding and Grounding: All analog signal wiring must utilize twisted-pair, shielded cabling. The shield must be connected to a clean earth ground at one end only to prevent ground loops and mitigate signal noise.\u003c\/li\u003e\n\u003cli\u003eSignal Separation: Route analog input signals away from high-voltage AC cabling and inductive loads to avoid electromagnetic interference that could influence high-precision measurements.\u003c\/li\u003e\n\u003cli\u003eTerminal Block Engagement: Confirm all wiring terminals are torqued to the manufacturer’s specification to prevent intermittent connections, which can lead to erratic signal fluctuations in the process data.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52435795738936,"sku":"IC200ALG260D","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IC200ALG260D.jpg?v=1780040074","url":"https:\/\/www.automodulexpert.com\/products\/ic200alg260d-general-electric-analog-input-module-new-original-stock","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}