{"product_id":"ic200alg261-ge-fanuc-analog-input-module-datasheet-technical-manual","title":"IC200ALG261 GE Fanuc Analog Input Module | Datasheet \u0026 Technical Manual","description":"\u003cp\u003eConfigured for precision signal acquisition in Versamax control networks, the \u003cstrong\u003eGE Fanuc IC200ALG261\u003c\/strong\u003e (\u003cstrong\u003eIC200ALG261\u003c\/strong\u003e Analog Input Module) provides direct physical\/electrical execution. This hardware component translates field-side analog signals into digitized values for controller processing within the Versamax I\/O architecture.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe IC200ALG261 is a fixed-configuration analog input module. The model designation indicates a standard high-density input architecture optimized for rapid scanning of process variables within the Versamax platform.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200ALG261\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eRefer to device label\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.25 lbs (0.11 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Versamax module footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 VDC backplane current consumption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe IC200ALG261 utilizes specialized input circuitry to maintain channel-to-channel isolation. This physical separation prevents ground loop formation when interfacing with multiple field instruments that may share different reference potentials. Maintaining this isolation is essential for accurate signal processing; therefore, proper cable shielding and single-point grounding are required to prevent noise injection across the input array.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the module support mixed signal types on the same input block?\u003c\/p\u003e\n\u003cp\u003eA: The IC200ALG261 is configured for specific signal ranges; users must verify the configuration settings in the controller software to match the field device output type (e.g., current or voltage).\u003c\/p\u003e\n\u003cp\u003eQ: How should the inputs be calibrated for maximum accuracy?\u003c\/p\u003e\n\u003cp\u003eA: Accuracy is maintained by utilizing a calibrated signal source during commissioning, allowing the user to map the raw digital counts to the required engineering units within the PLC configuration.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRoute all analog input wiring in dedicated cable trays to ensure maximum separation from high-voltage AC lines, reducing the risk of induced noise.\u003c\/li\u003e\n\u003cli\u003eUse shielded, twisted-pair cabling for all connections; terminate shields to the system ground bus at the cabinet entry to prevent EMI propagation.\u003c\/li\u003e\n\u003cli\u003eEnsure all terminal blocks are firmly seated onto the carrier to maintain low contact resistance, which is critical for minimizing signal drift.\u003c\/li\u003e\n\u003cli\u003eBefore applying power, verify the wiring polarity of each input channel to prevent potential damage to the input sensing circuits.\u003c\/li\u003e\n\u003cli\u003eMonitor the input status via the PLC diagnostic registers to identify and troubleshoot open-circuit or out-of-range signal conditions immediately.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52443255931192,"sku":"IC200ALG261","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IC200ALG262E.jpg?v=1779867875","url":"https:\/\/www.automodulexpert.com\/products\/ic200alg261-ge-fanuc-analog-input-module-datasheet-technical-manual","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}