{"product_id":"ic200alg320a-ge-versamax-analog-output-module-datasheet","title":"IC200ALG320A GE VersaMax Analog Output Module | Datasheet","description":"\u003cp\u003eConfigured for precision current signal transmission in VersaMax control networks, the \u003cstrong\u003eGE Fanuc IC200ALG320A\u003c\/strong\u003e (\u003cstrong\u003eIC200ALG320A\u003c\/strong\u003e Analog Output Module) provides direct physical\/electrical execution. This hardware component translates digital output values from the controller into proportional analog current signals for final control element positioning.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe IC200ALG320A is a fixed-configuration analog output module. The \"A\" suffix denotes the initial hardware design iteration, providing standard 4-point current output capability within the VersaMax I\/O platform.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200ALG320A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE VersaMax\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eRefer to device label\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e10.9 cm x 6.4 cm x 5.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 VDC backplane nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e4-point current output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol\u003c\/h3\u003e\n\u003cp\u003eThe IC200ALG320A facilitates process control by generating standard current outputs proportional to internal digital control words. When integrated into control loops, the module ensures consistent current delivery for actuators or positioning devices. Implementation requires correct impedance matching between the module output stage and the field device load. Users must ensure that the total loop resistance remains within the specified range to maintain signal accuracy and prevent output saturation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the IC200ALG320A support channel-to-channel isolation?\u003c\/p\u003e\n\u003cp\u003eA: The module is designed with common-referenced outputs. If electrical isolation between individual output channels is required for the specific application, external signal isolators must be installed.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module handle a loss of backplane communication?\u003c\/p\u003e\n\u003cp\u003eA: Upon detection of a backplane communication fault, the module can be configured to either hold the last valid output state or transition to a predefined safe-state value.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the terminal base is securely mounted to the DIN rail to guarantee stable electrical contact with the backplane bus.\u003c\/li\u003e\n\u003cli\u003eUse shielded, twisted-pair cabling for all analog output signal runs to mitigate electromagnetic interference from power lines or high-frequency drives.\u003c\/li\u003e\n\u003cli\u003eGround the cable shields at a single point, ideally at the cabinet's earth ground bus, to prevent ground loops that could introduce noise into the output signal.\u003c\/li\u003e\n\u003cli\u003eVerify that the total loop resistance of the connected field devices does not exceed the maximum rated load resistance of the module.\u003c\/li\u003e\n\u003cli\u003eConfirm that the terminal block locking mechanism is fully engaged to prevent signal disconnection due to vibration or thermal expansion.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52443245707576,"sku":"IC200ALG320A","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IC200ALG320.jpg?v=1778812152","url":"https:\/\/www.automodulexpert.com\/products\/ic200alg320a-ge-versamax-analog-output-module-datasheet","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}