{"product_id":"ic200alg320h-ge-versamax-analog-output-module","title":"IC200ALG320H GE VersaMax Analog Output Module","description":"\u003cp data-path-to-node=\"1\"\u003eThe \u003cb data-path-to-node=\"1\" data-index-in-node=\"4\"\u003eGE IC200ALG320H\u003c\/b\u003e, also cataloged as the \u003cb data-path-to-node=\"1\" data-index-in-node=\"43\"\u003eIC200ALG320H\u003c\/b\u003e Analog Output Module, operates as a dedicated hardware component for multi-channel signal regulation within VersaMax industrial control networks.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"2\"\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp data-path-to-node=\"3\"\u003eThe \u003cb data-path-to-node=\"3\" data-index-in-node=\"4\"\u003eIC200ALG320H\u003c\/b\u003e belongs to the VersaMax I\/O series. The \"H\" suffix represents the specific hardware iteration level, denoting the current engineering revision for this analog output module.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"4\"\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,1,0,0\"\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,1,1,0\"\u003eIC200ALG320H\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,2,0,0\"\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,2,1,0\"\u003eGE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,3,0,0\"\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,3,1,0\"\u003eRefer to original shipping documentation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,4,0,0\"\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,4,1,0\"\u003e0.35 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,5,0,0\"\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,5,1,0\"\u003e118 mm x 94 mm x 22.6 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,6,0,0\"\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,6,1,0\"\u003e0 deg C to 60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,7,0,0\"\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,7,1,0\"\u003eBackplane dependent\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,8,0,0\"\u003eHumidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,8,1,0\"\u003e5% to 95% non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-path-to-node=\"6\"\u003eProfinet \/ EtherNet\/IP deterministic networks\u003c\/h3\u003e\n\u003cp data-path-to-node=\"7\"\u003eThe module utilizes backplane bus communication velocity to process digital-to-analog conversion commands from the host controller. By leveraging deterministic network traffic, the \u003cb data-path-to-node=\"7\" data-index-in-node=\"181\"\u003eIC200ALG320H\u003c\/b\u003e ensures that output signals are updated within the specified controller scan cycles. Firmware flash compatibility is integrated to allow for system-wide updates, ensuring the module remains aligned with current PLC backplane communication standards and performance requirements.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"8\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp data-path-to-node=\"9\"\u003eQ: Does the module support hot-swapping under power?\u003c\/p\u003e\n\u003cp data-path-to-node=\"9\"\u003eA: The module is designed for compatibility with VersaMax hot-swap procedures, allowing for field replacement without removing power from the backplane, provided local safety protocols are followed.\u003c\/p\u003e\n\u003cp data-path-to-node=\"10\"\u003eQ: Is external power required for the analog output loops?\u003c\/p\u003e\n\u003cp data-path-to-node=\"10\"\u003eA: Yes, an external 24 VDC power supply is typically required to provide the loop power necessary for driving connected field devices.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"12\"\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col start=\"1\" data-path-to-node=\"13\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,0,0\"\u003eEnsure the mounting surface is clean and free of conductive debris before attaching the module carrier to the DIN-rail.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,1,0\"\u003eConfirm that the system power is OFF before seating the module onto the backplane connector to prevent electrical transients.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,2,0\"\u003eTerminate signal lines using shielded cables, and ensure the shield is grounded at the panel entry to minimize common-mode noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,3,0\"\u003eVerify that the output load impedance matches the module output rating to prevent signal clipping or output stage overheating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,4,0\"\u003eCheck for secure latching of the module to the carrier base to maintain consistent bus communication and mechanical vibration resistance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52429882261816,"sku":"IC200ALG320H","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IC200ALG320.jpg?v=1778812152","url":"https:\/\/www.automodulexpert.com\/products\/ic200alg320h-ge-versamax-analog-output-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}