{"product_id":"ic200alg321j-ge-fanuc-emerson-analog-output-module-datasheet","title":"IC200ALG321J GE Fanuc Emerson Analog Output Module Datasheet","description":"\u003cp\u003eConfigured for precision signal regulation in VersaMax control networks, the \u003cstrong\u003eGE Fanuc Emerson IC200ALG321J\u003c\/strong\u003e (\u003cstrong\u003eIC200ALG321J\u003c\/strong\u003e Analog Output Module) provides direct physical\/electrical execution of 4-point analog current output control.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eIC200ALG321J\u003c\/strong\u003e is designated as a 4-channel analog output module. The suffix \"J\" indicates the specific hardware revision level, which incorporates standardized circuitry for current loop regulation within the VersaMax I\/O family.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200ALG321J\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eRefer to original shipping documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.20 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard VersaMax I\/O footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e4 isolated analog current outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Range\u003c\/td\u003e\n\u003ctd\u003e4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP deterministic networks\u003c\/h3\u003e\n\u003cp\u003eThe module interfaces with the primary controller backplane to maintain high-speed bus communication velocity. This deterministic data exchange allows the module to update its analog output values in alignment with the master controller's scan cycle. Firmware flash compatibility is supported, ensuring that the module can be updated to meet changes in backplane communication protocols or internal data processing requirements. Each of the 4 output channels is designed for low-latency signal conversion, supporting accurate regulation of external field actuators.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 4-20 mA outputs be used to drive loads with high impedance?\u003c\/p\u003e\n\u003cp\u003eA: The module is designed to drive loads within a standard ohmic range; refer to the load resistance specifications to ensure the output current remains within the 4-20 mA accuracy limits.\u003c\/p\u003e\n\u003cp\u003eQ: Is external loop power required for this module?\u003c\/p\u003e\n\u003cp\u003eA: This module typically requires an external 24 VDC power supply to drive the current loops; check the module wiring diagram for specific power input terminal requirements.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the module on the appropriate VersaMax I\/O carrier base, ensuring the module latch is fully engaged for mechanical stability.\u003c\/li\u003e\n\u003cli\u003eTerminate the 4-20 mA current loop wiring using shielded twisted-pair cables to mitigate induced noise.\u003c\/li\u003e\n\u003cli\u003eEnsure the shield drain wire is connected to a chassis ground at the control cabinet entry to maintain signal integrity.\u003c\/li\u003e\n\u003cli\u003eVerify that the output load resistance does not exceed the maximum rating to prevent saturation or output signal distortion.\u003c\/li\u003e\n\u003cli\u003ePerform a loop check by commanding output values (4 mA, 12 mA, 20 mA) to verify calibrated response at the field device.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52429826064696,"sku":"IC200ALG321J","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IC200ALG321_2.jpg?v=1739528614","url":"https:\/\/www.automodulexpert.com\/products\/ic200alg321j-ge-fanuc-emerson-analog-output-module-datasheet","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}