{"product_id":"ic200alg326f-ge-fanuc-analog-output-module-datasheet-technical-manual","title":"IC200ALG326F GE Fanuc Analog Output Module Datasheet \u0026 Technical Manual","description":"\u003cp\u003eConfigured for precision signal output in Versamax control networks, the \u003cstrong\u003eGE Fanuc IC200ALG326F\u003c\/strong\u003e (\u003cstrong\u003eIC200ALG326F\u003c\/strong\u003e Analog Output Module) provides direct physical\/electrical execution. This hardware component translates 13-bit digital output values from the controller into precise analog voltage or current signals for industrial process control.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe IC200ALG326F is a high-resolution analog output module. The \"F\" suffix indicates the production revision level, incorporating refined internal D\/A conversion circuitry to maintain 13-bit output accuracy and low signal drift under varying load conditions.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200ALG326F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eRefer to device label\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.44 lbs (0.20 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Versamax module footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 VDC backplane current consumption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e13-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe IC200ALG326F maintains data integrity through deterministic backplane communication within the Versamax system. The module maps the 13-bit digital data word into the corresponding analog signal output synchronously with the controller's I\/O update cycle. Users must ensure that the host PLC communication module supports the required data width for the 13-bit resolution to prevent truncation of the output signal. Firmware compatibility must be verified to ensure precise timing during the conversion process and stable signal delivery to the field actuator.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the IC200ALG326F provide individual channel isolation?\u003c\/p\u003e\n\u003cp\u003eA: The module architecture relies on common-referenced outputs. For applications requiring complete galvanic isolation between output channels, external signal isolators must be integrated into the field wiring loop.\u003c\/p\u003e\n\u003cp\u003eQ: How is the output resolution of 13-bit utilized in the control logic?\u003c\/p\u003e\n\u003cp\u003eA: The 13-bit resolution provides high granularity for control loops, allowing the controller to command very fine increments of voltage or current, which is critical for precision positioning of valve actuators or variable frequency drives.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the module is fully seated on the terminal base to achieve a reliable connection to the backplane power and data bus.\u003c\/li\u003e\n\u003cli\u003eUse high-quality shielded, twisted-pair cable for all analog signal runs to minimize electromagnetic interference (EMI) and radio frequency interference (RFI).\u003c\/li\u003e\n\u003cli\u003eGround the shield at the cabinet end only to prevent the formation of ground loops that could introduce errors into the 13-bit analog signal.\u003c\/li\u003e\n\u003cli\u003eVerify the load impedance of the connected field device to ensure it falls within the module's rated operating range, preventing output saturation or signal clipping.\u003c\/li\u003e\n\u003cli\u003eRoute analog signal wiring in conduits separate from high-voltage AC lines to maintain signal purity and prevent cross-talk.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52443349418296,"sku":"IC200ALG326F","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IC200ALG326H2.jpg?v=1779239848","url":"https:\/\/www.automodulexpert.com\/products\/ic200alg326f-ge-fanuc-analog-output-module-datasheet-technical-manual","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}