This IC200BEM002 Profibus-DP Slave Module was manufactured by GE FANUC, In Stock, 100% Guaranteed Brand New and Authentic. Link to More Information

 
Manufacturer:
GE FANUC
Part Number:
IC200BEM002
Product type:
Country of Origin:
USA
Condition:
New With Original Package
Shipping Port:
ShangHai, Xiamen
Warranty:
12 Months
Collections:
 

Configured for network communications in VersaMax control networks, the General Electric IC200BEM002 (IC200BEM002 PLC Network Communications Profibus-DP Slave) provides direct physical/electrical execution of data exchange between fieldbus segments and the primary controller.

Hardware Specifications

Parameter Specification
Model IC200BEM002
Brand General Electric
Origin USA
Weight 0.12 kg
Dimensions 12.7 cm x 6.5 cm x 5.5 cm
Operating Temp Standard Industrial (-20 deg C to 60 deg C)
Power Consumption < 2 W
Function Profibus-DP Slave Interface

Profinet / EtherNet/IP deterministic networks

The module acts as a slave node within the Profibus-DP architecture, facilitating deterministic data throughput between the local backplane and the master controller. It maintains consistent communication cycle times to ensure process variables are updated according to the master PLC scan rate. The module supports parameterization via GSD files, allowing the host network to identify slave diagnostics, I/O mapping, and baud rate settings automatically. Logic timing within the slave interface prevents bus contention and optimizes the available bandwidth for cyclic data transfers.

Frequently Asked Questions

Q: Does the IC200BEM002 require a specific GSD file for integration into a master network?

A: Yes, integration into a Profibus-DP master network requires the specific GSD file corresponding to the hardware revision of the IC200BEM002 to define the I/O exchange parameters.

Q: Is the communication port isolated from the module's internal logic?

A: The Profibus-DP interface includes galvanic isolation to prevent ground loop noise from affecting the module backplane and the local PLC CPU.

Field Installation Guidelines

  1. Mount the module onto the VersaMax I/O carrier, ensuring the backplane connector is fully seated to maintain bus continuity.
  2. Utilize standard 9-pin D-sub connectors for the Profibus cabling. Ensure the cable is terminated with a 220 Ohm resistor at both ends of the segment to maintain signal integrity.
  3. Verify that the bus address switches are correctly set before applying power, as address changes are typically registered only during power-up or system reset.
  4. Route communication cables at a minimum distance of 200 mm from high-voltage AC lines to mitigate electromagnetic interference.
  5. Confirm the cable shield is bonded to the ground rail at the cabinet entry point to effectively drain induced noise.
Quick Quotes Receive price & availability FAST from our dedicated customer service team.
Delivery Expedited, Freight, And International Shipping Available.
Condition 100% New with Original Package
Payment We accept American Express, Discover, MasterCard, PayPal, and Visa. Our site is secured by RapidSSL.
Shipping Port ShangHai, Xiamen
Warranty 12 Months
Q: Is Our Pricing Competitive?
A: Yes, we collaborate with over 50 countries worldwide. As a top supplier in China, we offer significant discounts based on market trends.
Q: What Is the Warranty Period?
A: All our new and original products come with a standard one-year warranty.
Q: What Payment Methods Do We Accept?
A: We require 100% T/T (Telegraphic Transfer) payment before shipping. For items with a lead time, a 30% deposit is needed upfront, and the remaining 70% is due before shipping. If you have a representative in China, you can arrange an RMB transfer through them.
Q: What Shipping Methods Do We Use?
A: We primarily use FedEx, DHL, UPS, and BRE for shipping. If you have an account with any of these carriers, you can handle shipping directly. We also offer free shipping to China-based freight forwarders.
Q: What Is Our Delivery Time?
A: Delivery usually takes 1-3 days after receiving the initial payment. For items with a lead time, shipping will occur according to the specified schedule.
Q: How Do We Package the Goods?
A: We ensure safe packaging with multiple layers of protection. Products are first placed in their original boxes and sealed with labels. A layer of bubble wrap is then added for collision protection during transit. Finally, the items are packed securely in durable boxes.
Q: How Can Customers Contact Us and Request a Quote?
A: You can reach out to us via email, WhatsApp, WeChat, Skype, or your preferred communication platform. Contact us with your needs, and we'll provide a prompt, customized quote.
 

Recently Viewed

Express Shipping icon
Express Shipping
Rapid delivery for your urgent requirements.
Large stock icon
Extensive Inventory
Large stock for immediate dispatch.
Quality Assurance Icon
Quality Assurance
Authentic, top-grade PLC & DCS components.
Global Service icon
Global Service
Supporting clients worldwide with dependable service.