{"product_id":"ic200dtx200-ge-fanuc-versamax-operator-interface-new-original-stock","title":"IC200DTX200 GE Fanuc Versamax Operator Interface New \u0026 Original Stock","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC200DTX200\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC200DTX200\u003c\/strong\u003e Operator Interface, operates as a dedicated hardware component for human-machine interaction and system monitoring within VersaMax platform networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eIC200DTX200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eOrigin\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eSubject to factory batch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eStandard VersaMax interface weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eStandard VersaMax DP enclosure footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e24 VDC nominal requirement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eInterface Type\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eVersaMax DP Operator Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eBackplane Bus Communication and Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe module communicates with the host controller via the VersaMax bus architecture, providing real-time data visualization and operator setpoint entry. The backplane bus communication velocity is optimized to ensure that screen updates and input responses remain synchronized with the PLC logic scan. Firmware flash compatibility is supported for system-wide updates, ensuring the interface maintains current protocol compatibility without requiring physical hardware modifications. I\/O density scaling is maintained by the unit as it provides a localized control point for data monitored across the distributed I\/O rack.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the unit support direct memory access to the host PLC?\u003c\/p\u003e\n\u003cp\u003eA: The operator interface performs reads and writes to assigned PLC memory registers to facilitate data exchange; users must define the register mapping within the engineering software to ensure correct data alignment.\u003c\/p\u003e\n\u003cp\u003eQ: Is the interface unit hot-swappable?\u003c\/p\u003e\n\u003cp\u003eA: No, the unit is a static operator interface device; power must be cycled and the device disconnected from the bus before any hardware installation or removal to prevent potential communication errors or hardware damage.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the operator interface into the panel cutout or on a standard DIN rail as specified by the enclosure design to maintain IP rating integrity.\u003c\/li\u003e\n\u003cli\u003eConnect the 24 VDC power supply to the interface terminal block, ensuring proper polarity to avoid internal circuit damage.\u003c\/li\u003e\n\u003cli\u003eUtilize a dedicated serial or bus communication cable to link the interface to the host controller, ensuring cable shields are grounded at the cabinet entry.\u003c\/li\u003e\n\u003cli\u003eMaintain physical separation between the interface communication lines and any high-power AC lines to prevent signal noise or electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eConfigure the communication parameters (baud rate, parity, station ID) within the interface firmware settings to match the host controller requirements.\u003c\/li\u003e\n\u003cli\u003ePerform a full system power-up cycle after installation to verify the initialization sequence and confirm active communication with the PLC.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52426125181240,"sku":"IC200DTX200","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IC200DTX2001.jpg?v=1779781438","url":"https:\/\/www.automodulexpert.com\/products\/ic200dtx200-ge-fanuc-versamax-operator-interface-new-original-stock","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}