{"product_id":"ic200mdd750-ge-fanuc-digital-input-module-new-original-stock","title":"IC200MDD750 GE Fanuc Digital Input Module New \u0026 Original Stock","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC200MDD750\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC200MDD750\u003c\/strong\u003e Digital Input Module, operates as a dedicated hardware component for high-density discrete signal acquisition within VersaMax network platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eIC200MDD750\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eOrigin\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eSubject to factory batch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eStandard VersaMax module weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eStandard VersaMax module footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eLogic side bus load dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eVoltage Range\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e12–24 V DC (nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003eInput Current\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003e7 mA at 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003eResponse Time\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003e0.5 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eBackplane Bus Communication and Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe module communicates via the VersaMax backplane, utilizing high-speed bus arbitration to maintain deterministic signal updates. Firmware flash compatibility is managed through the host CPU, allowing for transparent integration within existing VersaMax configurations. The high-density I\/O density scaling provided by this 32-point module allows for optimized rack space utilization, ensuring that the backplane bus communication velocity remains stable even when multiple high-density modules are installed in a single node.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does this module support hot-swapping during operation?\u003c\/p\u003e\n\u003cp\u003eA: The VersaMax system architecture permits the removal and insertion of I\/O modules while the backplane is powered, provided the specific safety protocols and rack configuration requirements are followed.\u003c\/p\u003e\n\u003cp\u003eQ: Are the inputs isolated from the backplane logic?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the input circuitry provides optical isolation between the field signal side and the backplane logic to prevent transient electrical noise from reaching the CPU.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the module securely onto a standard 35 mm DIN rail or compatible VersaMax carrier.\u003c\/li\u003e\n\u003cli\u003eEnsure the field wiring is terminated according to the pinout diagram, maintaining consistent positive logic polarity.\u003c\/li\u003e\n\u003cli\u003eUse shielded cable for field input wiring to minimize electromagnetic interference, ensuring the shield is grounded at the cabinet entry point.\u003c\/li\u003e\n\u003cli\u003eVerify the physical engagement of the module with the carrier to ensure the electrical backplane connector is fully seated.\u003c\/li\u003e\n\u003cli\u003eObserve the individual channel LED indicators during commissioning to confirm input signal status and verify loop integrity.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52426098966840,"sku":"IC200MDD750","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IC200MDL650E.jpg?v=1779699804","url":"https:\/\/www.automodulexpert.com\/products\/ic200mdd750-ge-fanuc-digital-input-module-new-original-stock","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}