{"product_id":"ic200mdd844k-ge-fanuc-mixed-i-o-module-new-original-stock","title":"IC200MDD844K GE Fanuc Mixed I\/O Module New \u0026 Original Stock","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC200MDD844K\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC200MDD844K\u003c\/strong\u003e Mixed I\/O Module, operates as a dedicated hardware component for discrete signal acquisition and relay-based control output within VersaMax platform networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eIC200MDD844K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eOrigin\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eSubject to factory batch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eStandard VersaMax module weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eStandard VersaMax module footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eLogic side bus load dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eInputs\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eDiscrete, 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eOutputs\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003eRelay, 2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eBackplane Bus Communication and Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe module facilitates signal processing via the VersaMax backplane, utilizing high-speed bus arbitration to maintain deterministic performance. The unit supports I\/O density scaling by consolidating both input and output functions into a single module slot, reducing the total hardware footprint. Firmware flash compatibility is managed through the host CPU, with the module acting as a transparent interface layer. Bus communication velocity is maintained across the rack, ensuring synchronized execution of control logic and field device actuation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Are the relay outputs isolated from each other?\u003c\/p\u003e\n\u003cp\u003eA: The relay outputs provide physical isolation between the load circuits; however, users must verify the specific terminal wiring to ensure proper grouping and protection against cross-circuit interference.\u003c\/p\u003e\n\u003cp\u003eQ: Can this module handle inductive loads on the relay outputs?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the relay outputs are rated for 2 A; however, when switching inductive loads, external suppression such as RC networks or flyback diodes must be installed to prevent contact pitting and extend the operational lifespan of the internal relays.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the module securely onto a standard 35 mm DIN rail or compatible VersaMax carrier base.\u003c\/li\u003e\n\u003cli\u003eEnsure all field power is removed before terminating signal or load wiring to the module terminal blocks.\u003c\/li\u003e\n\u003cli\u003eRoute input signal wires and output load cables in separate conduits to minimize crosstalk and induced electrical noise.\u003c\/li\u003e\n\u003cli\u003eVerify that the 24 VDC input logic polarity matches the sourcing\/positive logic configuration of the field devices.\u003c\/li\u003e\n\u003cli\u003eCheck that load current does not exceed the 2 A per point rating of the relay outputs, utilizing external fusing to protect the internal contacts.\u003c\/li\u003e\n\u003cli\u003eObserve the front-panel status LEDs during system commissioning to confirm proper input activation and output relay state switching.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52426210246968,"sku":"IC200MDD844K","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IC200MDD844K.jpg?v=1779781439","url":"https:\/\/www.automodulexpert.com\/products\/ic200mdd844k-ge-fanuc-mixed-i-o-module-new-original-stock","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}