{"product_id":"ic200mdl143-ge-fanuc-discrete-input-module-datasheet-technical-manual","title":"IC200MDL143 GE Fanuc Discrete Input Module | Datasheet \u0026 Technical Manual","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC200MDL143\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC200MDL143\u003c\/strong\u003e Discrete Input Module, operates as a dedicated hardware component for sensing binary field signals within Versamax system networks. This module provides direct physical\/electrical execution, converting discrete electrical states into digital data packets for transmission across the system backplane to the controller CPU.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200MDL143\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eVerify via product label\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.11 kg (0.25 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Versamax module footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eBackplane dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Type\u003c\/td\u003e\n\u003ctd\u003eDiscrete Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eVersamax Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe IC200MDL143 module is optimized for deterministic performance within the Versamax backplane, ensuring that discrete input transitions are captured and transmitted with minimal latency. It supports I\/O density scaling by allowing multiple high-speed input points to be monitored concurrently without degrading communication bus velocity. When integrated into distributed Profinet or EtherNet\/IP nodes, the module architecture ensures precise alignment of input data states within the controller's cyclic scan window. Firmware flash compatibility is supported, allowing for consistent diagnostic reporting and operational status updates across the industrial control network.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can this module be configured to interface with AC or DC input signals?\u003c\/p\u003e\n\u003cp\u003eA: The IC200MDL143 is designed for specific input voltage ranges; verify the module nameplate and datasheet to ensure compatibility with your field signal voltage (e.g., 24 VDC vs 120 VAC) before installation.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module handle signal debounce for mechanical contacts?\u003c\/p\u003e\n\u003cp\u003eA: The internal circuitry of the module typically includes fixed or configurable hardware filtering to prevent contact bounce from triggering multiple inputs during a single state transition.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDIN-Rail Mounting: Secure the module onto a 35 mm DIN rail. Ensure the backplane connector is properly aligned and the locking latches are fully engaged to prevent intermittent signal loss.\u003c\/li\u003e\n\u003cli\u003eWiring Shielding: Use twisted-pair cabling for all input signals. Terminate the shield at the common ground point to minimize susceptibility to electromagnetic interference (EMI) from adjacent power conduits.\u003c\/li\u003e\n\u003cli\u003eGrounding: Connect the module’s grounding terminal to the main equipment chassis ground. A low-impedance ground path is essential to protect the discrete input circuitry from electrostatic surges.\u003c\/li\u003e\n\u003cli\u003eTerminal Tightening: Ensure that all field wires are secured within the terminal blocks to the manufacturer's torque specifications to prevent loose connections, which can lead to erratic input data logging.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52435969179960,"sku":"IC200MDL143","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IC200MDL143.jpg?v=1780040073","url":"https:\/\/www.automodulexpert.com\/products\/ic200mdl143-ge-fanuc-discrete-input-module-datasheet-technical-manual","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}