{"product_id":"ic200mdl240b-ge-versamax-ac-input-module-new-original-stock","title":"IC200MDL240B GE VersaMax AC Input Module New \u0026 Original Stock","description":"\u003cp\u003eThe \u003cstrong\u003eGE IC200MDL240B\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC200MDL240B\u003c\/strong\u003e Discrete Input Module, operates as a dedicated hardware component for high-density AC signal acquisition within VersaMax control network platforms. The module provides 16 discrete input points, organized into two isolated groups of 8, enabling the interface of 120 VAC field signals with the PLC backplane. It performs signal rectification and buffering to ensure consistent logic status updates across the control system.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200MDL240B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.35 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e110 x 66.8 x 50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial standard range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e110 mA max backplane current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Points\u003c\/td\u003e\n\u003ctd\u003e16 (2 groups of 8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe IC200MDL240B is engineered for integration into industrial control architectures, supporting deterministic data throughput to the CPU. The module features an on-state voltage range of 70–132 VAC and an off-state threshold of 0–40 VAC, providing clear state differentiation for field sensors. Backplane bus communication velocity is maintained through high-speed internal scanning, and firmware flash compatibility allows the module to align with existing PLC I\/O update cycles, ensuring that input transitions are captured accurately without significant latency.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the two groups of 8 inputs be powered by different voltage sources?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the 16 inputs are organized into two groups of 8, allowing each group to be powered by independent 120 VAC power sources, provided they share a common reference within their respective group.\u003c\/p\u003e\n\u003cp\u003eQ: What are the consequences of input voltage falling between 40 VAC and 70 VAC?\u003c\/p\u003e\n\u003cp\u003eA: The voltage range between 40 VAC and 70 VAC is undefined. Input signals in this range may result in unpredictable logic states, potentially causing intermittent status updates. Always ensure field signals are within the specified on-state or off-state ranges.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the module to the VersaMax rack system by ensuring the rear latching mechanism is fully engaged for mechanical stability.\u003c\/li\u003e\n\u003cli\u003eUse shielded cable for AC signal wiring to minimize inductive crosstalk between neighboring signal runs in the wire duct.\u003c\/li\u003e\n\u003cli\u003eConnect input field devices to the module terminals; ensure the return path for each group is properly terminated to the source common.\u003c\/li\u003e\n\u003cli\u003eMaintain the required clearance around the module chassis to allow for convection cooling, as AC input modules dissipate heat during continuous operation.\u003c\/li\u003e\n\u003cli\u003eVerify the 250 VAC continuous isolation rating if the module is utilized in environments where high-voltage transient spikes are common on the field wiring.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52432165994808,"sku":"IC200MDL240B","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IC200MDL240B2.jpg?v=1779953580","url":"https:\/\/www.automodulexpert.com\/products\/ic200mdl240b-ge-versamax-ac-input-module-new-original-stock","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}