{"product_id":"ic200mdl240d-ge-fanuc-discrete-input-module-new-original-stock","title":"IC200MDL240D GE Fanuc Discrete Input Module | New \u0026 Original Stock","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC200MDL240D\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC200MDL240\u003c\/strong\u003e Discrete Input Module, operates as a dedicated hardware component for multi-point signal acquisition within Versamax control networks.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIC200\u003c\/strong\u003e: Versamax series product identifier.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMDL\u003c\/strong\u003e: Module classification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e240\u003c\/strong\u003e: 16-point discrete input configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eD\u003c\/strong\u003e: Hardware revision level indicating design iteration for backplane signal synchronization.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200MDL240D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSubject to manufacturing batch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.38 lbs (0.17 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Versamax I\/O form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDefined by backplane load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e16-point discrete input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe IC200MDL240D converts incoming 16-point discrete signals into digital data packets for transmission over the Versamax backplane. In Profinet or EtherNet\/IP architectures, the module facilitates deterministic data exchange by providing high-speed state monitoring of connected field sensors. Firmware flash compatibility is essential to ensure that the register mapping and input filter times are accurately registered by the CPU. Users must maintain bus communication velocity by ensuring the module is correctly seated, preventing signal degradation that could lead to packet retransmissions or increased input-to-logic scan latency.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the IC200MDL240D support hot-swapping under power?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module supports hot-swapping capability within the Versamax system, allowing for replacement without de-energizing the main backplane power.\u003c\/p\u003e\n\u003cp\u003eQ: How can I verify that an input signal is detected by the controller?\u003c\/p\u003e\n\u003cp\u003eA: Each channel features a corresponding status indicator on the module front panel, which mirrors the logic state currently being reported to the CPU.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify that the input voltage matches the module rating before connecting field devices to prevent damage to the internal isolation circuitry.\u003c\/li\u003e\n\u003cli\u003eEnsure all signal wiring is routed away from high-voltage cables to mitigate electromagnetic interference and false input triggering.\u003c\/li\u003e\n\u003cli\u003eSecure the module to the DIN-rail using the integrated locking mechanism to ensure stable electrical contact with the backplane bus.\u003c\/li\u003e\n\u003cli\u003eUse appropriate wire ferrules to maintain secure terminal block connections and prevent loosening due to industrial ambient vibration.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52450971025720,"sku":"IC200MDL240D","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IC200MDL240B2.jpg?v=1779953580","url":"https:\/\/www.automodulexpert.com\/products\/ic200mdl240d-ge-fanuc-discrete-input-module-new-original-stock","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}