{"product_id":"ic200mdl650e-ge-fanuc-discrete-input-module-new-original-stock","title":"IC200MDL650E GE Fanuc Discrete Input Module New \u0026 Original Stock","description":"\u003cp\u003eConfigured for high-density signal acquisition in VersaMax platforms, the \u003cstrong\u003eGE Fanuc IC200MDL650E\u003c\/strong\u003e (\u003cstrong\u003eIC200MDL650E\u003c\/strong\u003e Discrete Input Module) provides direct physical\/electrical execution for 32 discrete input points.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIC200\u003c\/strong\u003e: VersaMax product series identifier.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMDL\u003c\/strong\u003e: Modular discrete I\/O component classification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e650\u003c\/strong\u003e: Identification for the 32-point input module category.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eE\u003c\/strong\u003e: Revision level indicating internal hardware iteration and production compatibility standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eIC200MDL650E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eOrigin\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eSubject to individual unit labeling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e0.14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eStandard VersaMax module form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e100 mA at 5 VDC (Backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eDiscrete Inputs\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e32 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eInput Voltage\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePLC Platform Compatibility and Bus Communication\u003c\/h3\u003e\n\u003cp\u003eThe IC200MDL650E interfaces with the host CPU or Network Interface Unit (NIU) via the VersaMax backplane bus. Firmware flash compatibility is managed through the system controller to ensure the module adheres to the deterministic I\/O scan timing required for 32-point processing. System configuration must account for the specific I\/O density scaling enabled by this unit, ensuring the memory map is accurately defined in the project configuration software. Backplane bus communication velocity is synchronous with the CPU cycle to maintain input data integrity.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the IC200MDL650E provide per-point galvanic isolation?\u003c\/p\u003e\n\u003cp\u003eA: No, the module provides common-referenced inputs. Isolation is not provided between individual points.\u003c\/p\u003e\n\u003cp\u003eQ: Is this module compatible with negative logic input sources?\u003c\/p\u003e\n\u003cp\u003eA: The IC200MDL650E is typically designed for positive logic (sourcing) configurations. Verify the specific voltage thresholds in the technical manual to ensure compatibility with field sensor output types.\u003c\/p\u003e\n\u003cp\u003eQ: Can the module be extracted while the rack is powered?\u003c\/p\u003e\n\u003cp\u003eA: While designed for VersaMax hot-swap capability, always follow site-specific safety protocols regarding the removal of I\/O modules under live power to avoid backplane communication transients.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Seat the module firmly onto the VersaMax I\/O carrier. Ensure the locking lever is engaged to guarantee solid contact with the backplane pins.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use appropriate wire sizes to populate the terminal blocks. Ensure that field wiring is routed to prevent physical strain on the module connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding:\u003c\/strong\u003e Terminate cable shields at the designated ground terminal provided on the I\/O carrier or the cabinet earth bus to minimize noise ingress from adjacent high-voltage lines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e Ensure the ambient temperature remains within the specified range. Monitor for adequate airflow if the module is installed in a high-density rack configuration to prevent thermal degradation of internal components.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52422438224184,"sku":"IC200MDL650E","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IC200MDL650E.jpg?v=1779699804","url":"https:\/\/www.automodulexpert.com\/products\/ic200mdl650e-ge-fanuc-discrete-input-module-new-original-stock","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}