{"product_id":"ic200mdl740g-ge-fanuc-output-module-new-original-stock","title":"IC200MDL740G GE Fanuc Output Module New \u0026 Original Stock","description":"\u003cp\u003eConfigured for discrete signal switching in VersaMax I\/O platforms, the \u003cstrong\u003eGE IC200MDL740G\u003c\/strong\u003e (\u003cstrong\u003eIC200MDL740G\u003c\/strong\u003e Positive Logic Output Module) provides direct physical electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200MDL740G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eStandardized Manufacturing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e5 cm x 11 cm x 6.68 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard Industrial Range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 V backplane: 50 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Points\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e10.2-30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Current per Point\u003c\/td\u003e\n\u003ctd\u003e0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e0.5 ms (On\/Off)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePLC Deterministic Network Communication and Backplane Integration\u003c\/h3\u003e\n\u003cp\u003eThe IC200MDL740G functions within the VersaMax backplane bus architecture, utilizing deterministic scan cycles to manage output state transitions. Data exchange between the module and the CPU is facilitated via the internal bus, requiring strict adherence to backplane power budgeting. The firmware ensures synchronized logic execution, maintaining consistent communication velocity across the I\/O rack. Users must verify that the cumulative backplane current consumption of all installed modules does not exceed the power supply capacity to maintain deterministic network stability.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does this module support channel-to-channel electrical isolation?\u003c\/p\u003e\n\u003cp\u003eA: No, the IC200MDL740G does not provide channel-to-channel isolation. All 16 points share a common return path.\u003c\/p\u003e\n\u003cp\u003eQ: Are there integrated fuses for output protection?\u003c\/p\u003e\n\u003cp\u003eA: No, this module does not contain internal fuses for individual outputs. External fusing is required to protect the load and internal circuitry from overcurrent conditions.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Ensure the module is securely snapped onto the DIN rail and locked into the carrier. Verify that the latching mechanism is fully engaged to maintain backplane bus connectivity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Connect the field power supply (10.2-30 VDC) to the appropriate terminals. Ensure wire gauges are selected based on the 0.5 A per point load requirement to prevent voltage drop.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Maintain proper chassis ground to minimize EMI. Keep high-voltage AC cabling physically separated from the DC output signal wiring to prevent inductive coupling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush Current:\u003c\/strong\u003e Ensure that connected loads do not exceed the 2.0 A inrush maximum for the 100 ms duration to prevent false logic triggering or hardware stress.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52429885276472,"sku":"IC200MDL740G","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IC200MDL740G1.jpg?v=1779867875","url":"https:\/\/www.automodulexpert.com\/products\/ic200mdl740g-ge-fanuc-output-module-new-original-stock","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}