{"product_id":"ic200mdl744-ge-fanuc-discrete-output-module-datasheet-technical-manual","title":"IC200MDL744 GE Fanuc Discrete Output Module | Datasheet \u0026 Technical Manual","description":"\u003cp\u003eConfigured for high-density DC signal switching in Versamax control networks, the \u003cstrong\u003eGE Fanuc IC200MDL744\u003c\/strong\u003e (\u003cstrong\u003eIC200MDL744\u003c\/strong\u003e Discrete Output Module) provides direct physical\/electrical execution. This hardware component interfaces controller logic with field devices by providing multiple points of DC output switching for industrial automation tasks.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe IC200MDL744 is a fixed-configuration discrete output module. The model number denotes a standardized output architecture within the Versamax I\/O product line, designed to provide consistent logic-to-field voltage conversion for various DC-operated control elements.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200MDL744\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eRefer to device label\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.00 lbs (0.45 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Versamax module footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 VDC backplane current consumption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eDiscrete Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe IC200MDL744 module utilizes the Versamax backplane bus to ensure precise synchronization between the host controller and field output states. Integration requires correct mapping of the output data bits within the controller configuration. The module supports deterministic network environments by maintaining high-speed throughput, which minimizes output jitter. Users must verify firmware flash compatibility with the backplane communication module to ensure stable data transmission during I\/O scanning cycles.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does this module support hot-swap capabilities during operation?\u003c\/p\u003e\n\u003cp\u003eA: The module is designed for hot-swapping within the Versamax system; however, users must disconnect field power from the terminal base prior to removal to prevent terminal arcing and protect the internal switching transistors.\u003c\/p\u003e\n\u003cp\u003eQ: How is the output logic defined for this module?\u003c\/p\u003e\n\u003cp\u003eA: The IC200MDL744 is configured for DC output logic, where the module provides the switched potential to the field load when the output channel is energized.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify that the terminal base is locked onto the 35 mm DIN rail or panel surface before inserting the module to ensure proper backplane connector alignment.\u003c\/li\u003e\n\u003cli\u003eEnsure that the total current draw does not exceed the internal trace rating; distribute field loads across output points to prevent thermal overloading of the module.\u003c\/li\u003e\n\u003cli\u003eRoute field wiring through dedicated conduits, keeping output lines separated from high-voltage AC cabling to prevent inductive noise injection.\u003c\/li\u003e\n\u003cli\u003eVerify the polarity of the DC field power supply before connecting it to the module's power input terminals to avoid permanent damage to the output stages.\u003c\/li\u003e\n\u003cli\u003eTighten all terminal connections to ensure low contact resistance, which is essential for maintaining the rated current capacity per point.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52443326906680,"sku":"IC200MDL744","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IC200MDL741J1.jpg?v=1779781438","url":"https:\/\/www.automodulexpert.com\/products\/ic200mdl744-ge-fanuc-discrete-output-module-datasheet-technical-manual","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}