{"product_id":"ic200pwr00-ge-fanuc-power-supply-module-datasheet-technical-manual","title":"IC200PWR00 GE Fanuc Power Supply Module Datasheet \u0026 Technical Manual","description":"\u003cp\u003eConfigured for power distribution in Versamax control networks, the \u003cstrong\u003eGE Fanuc IC200PWR00\u003c\/strong\u003e (\u003cstrong\u003eIC200PWR00\u003c\/strong\u003e Power Supply Module) provides direct physical\/electrical execution. This module functions as the primary power source for the backplane, converting input voltage into regulated DC power required for the operation of modular I\/O and communication components.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200PWR00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eVerify via product label\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.14 kg (0.31 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Versamax module footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eApplication dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Type\u003c\/td\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eVersamax Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe IC200PWR00 ensures backplane bus communication velocity by providing a stable voltage reference for all interconnected modules. In deterministic industrial networks, consistent power delivery is necessary to maintain the timing accuracy of Profinet and EtherNet\/IP data cycles. The module architecture prevents voltage sag during high-load I\/O operations, ensuring that the communication processors do not experience jitter or reset conditions. Firmware flash compatibility is supported for integrated power monitoring variants, allowing the host controller to track power health and load status in real-time.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does this module support redundant power supply configurations?\u003c\/p\u003e\n\u003cp\u003eA: Redundancy depends on the backplane architecture and the presence of dual-power-input module support; confirm your specific rack design before attempting parallel power injection.\u003c\/p\u003e\n\u003cp\u003eQ: How is the module protected against short-circuit events on the backplane?\u003c\/p\u003e\n\u003cp\u003eA: The module contains internal current-limiting protection to prevent damage to the backplane bus in the event of an output short circuit or excessive load draw.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDIN-Rail Mounting: Ensure the module is snapped firmly onto the DIN rail and the locking tabs are engaged. This provides the necessary mechanical stability and grounding path via the rail.\u003c\/li\u003e\n\u003cli\u003eWiring Specifications: Use appropriate wire cross-sections for the power input to ensure compliance with voltage drop requirements. Ensure terminals are torqued according to specifications to prevent overheating.\u003c\/li\u003e\n\u003cli\u003eThermal Management: Allow for adequate clearance around the module to facilitate passive heat dissipation, as power regulation generates heat that must be vented to maintain operational life.\u003c\/li\u003e\n\u003cli\u003eGrounding: Connect the chassis ground to a low-impedance earth bus. This is critical for noise immunity and protecting the module from high-voltage transients on the power line.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52435977437496,"sku":"IC200PWR00","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IC200PWR001A.jpg?v=1779953580","url":"https:\/\/www.automodulexpert.com\/products\/ic200pwr00-ge-fanuc-power-supply-module-datasheet-technical-manual","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}