{"product_id":"ic200pwr001d-general-electric-power-supply-datasheet","title":"IC200PWR001D General Electric Power Supply | Datasheet","description":"\u003cp\u003eConfigured for rack-level power distribution in VersaMax control networks, the \u003cstrong\u003eGE Fanuc IC200PWR001D\u003c\/strong\u003e (\u003cstrong\u003eIC200PWR001D\u003c\/strong\u003e Power Supply Module) provides direct physical\/electrical execution. This hardware component converts incoming line voltage into regulated DC levels required to energize the backplane and associated I\/O modules within the VersaMax I\/O platform.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe IC200PWR001D is a dedicated power supply unit. The \"D\" suffix denotes the hardware revision level, which includes integrated thermal management and surge protection circuitry compliant with standard industrial power distribution requirements for VersaMax systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200PWR001D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 KG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e5.1 cm x 12.7 cm x 6.3 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eInput line voltage conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eRack-level power distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSurge Voltage Protection Limits\u003c\/h3\u003e\n\u003cp\u003eThe IC200PWR001D incorporates internal filtering and surge suppression to protect the backplane electronics from transient voltage spikes prevalent in industrial environments. These protection limits are engineered to divert high-energy transients away from the sensitive logic components of the controller. Users must ensure that the primary AC or DC input source is correctly fused at the source to prevent catastrophic failure during short-circuit events or extreme overvoltage conditions exceeding the module's clamp voltage.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can this power supply be connected in parallel with another supply to increase current capacity?\u003c\/p\u003e\n\u003cp\u003eA: No, the IC200PWR001D is not designed for parallel operation. Connecting multiple power supplies in parallel can cause circulating currents and result in permanent damage to the modules.\u003c\/p\u003e\n\u003cp\u003eQ: How is the status of the power supply monitored during system operation?\u003c\/p\u003e\n\u003cp\u003eA: The module features onboard status indicators; if the primary or secondary DC output rails fall below the nominal voltage threshold, the indicators will transition to a fault state, signaling the need for diagnostic inspection.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the module is mounted in a vertical orientation to facilitate proper convective cooling and prevent heat buildup within the enclosure.\u003c\/li\u003e\n\u003cli\u003eVerify that the input power source matches the voltage rating specified on the module label before making final electrical connections.\u003c\/li\u003e\n\u003cli\u003eUtilize dedicated wiring for the power supply input; avoid routing AC power lines in the same conduit as low-voltage I\/O signals to minimize electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eMaintain a secure ground connection to the chassis earth terminal to ensure the internal surge protection and noise filtering circuits function as intended.\u003c\/li\u003e\n\u003cli\u003eRegularly inspect terminal block connections for signs of thermal degradation or oxidation, particularly in high-vibration or high-temperature industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52443385168184,"sku":"IC200PWR001D","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IC200PWR001A.jpg?v=1779953580","url":"https:\/\/www.automodulexpert.com\/products\/ic200pwr001d-general-electric-power-supply-datasheet","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}