{"product_id":"ic200pwr10-general-electric-power-supply-new-original-stock","title":"IC200PWR10 General Electric Power Supply New \u0026 Original Stock","description":"\u003cp\u003eThe \u003cstrong\u003eGE General Electric IC200PWR10\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC200PWR10\u003c\/strong\u003e Power Supply Module, operates as a dedicated hardware component for logic power conversion and backplane distribution within VersaMax industrial control platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eIC200PWR10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eOrigin\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e5.1 x 12.7 x 4.4 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eSystem load dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eFunction\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eLogic power supply for backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eBackplane Bus Communication and Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe module serves as the primary energy source for the VersaMax rack, ensuring the necessary backplane bus communication velocity for connected CPU and I\/O modules. By maintaining a stable DC rail voltage, the unit ensures deterministic signal processing across the backplane. The module is engineered for seamless integration with the VersaMax bus architecture; as a hardware-level power distribution component, it does not require firmware flash compatibility. It supports effective I\/O density scaling by providing the necessary current overhead to power expanded node configurations while maintaining low-noise power regulation for sensitive logic circuitry.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is this module capable of providing field power to sensors?\u003c\/p\u003e\n\u003cp\u003eA: No, the IC200PWR10 is strictly designed to supply power to the internal backplane logic, CPUs, and communication modules. Field devices require an independent, external power source.\u003c\/p\u003e\n\u003cp\u003eQ: Does this module support redundant power configurations?\u003c\/p\u003e\n\u003cp\u003eA: Users must consult the system rack manual to determine if the specific controller configuration permits parallel power supply operation or if the module is intended for a single-source configuration.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify that all primary AC\/DC input power is disconnected before installing the module into the power supply slot.\u003c\/li\u003e\n\u003cli\u003eEnsure the rear connector is fully seated onto the backplane to prevent intermittent power loss or bus communication faults.\u003c\/li\u003e\n\u003cli\u003eInstall the module in a location that permits adequate vertical airflow to comply with the 0 to 60 deg C operating temperature range.\u003c\/li\u003e\n\u003cli\u003eEnsure the chassis is correctly grounded to a common plant earth point to provide a stable reference for the logic power return.\u003c\/li\u003e\n\u003cli\u003eVerify input voltage levels before applying power to ensure they remain within the specified operating tolerance of the module.\u003c\/li\u003e\n\u003cli\u003eObserve the diagnostic LEDs during initialization to confirm the power supply is outputting the correct rail voltages and that the system is ready for operation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52426208346424,"sku":"IC200PWR10","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IC200PWR101E.jpg?v=1779781438","url":"https:\/\/www.automodulexpert.com\/products\/ic200pwr10-general-electric-power-supply-new-original-stock","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}