{"product_id":"ic200ual006-ge-fanuc-micro-plc-datasheet-technical-manual","title":"IC200UAL006 GE Fanuc Micro PLC Datasheet \u0026 Technical Manual","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC200UAL006\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC200UAL006\u003c\/strong\u003e Micro Programmable Logic Controller, operates as a dedicated hardware component for localized logic execution and sequence control within Versamax platforms.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe IC200UAL006 represents a compact, all-in-one controller architecture. The model designator confirms its status as a base CPU unit within the micro series, integrated with onboard I\/O capabilities and communication ports required for standalone automation applications.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200UAL006\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eRefer to device label\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.00 lbs (0.91 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Versamax micro-controller housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eLogic execution and I\/O management\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe IC200UAL006 functions as the primary execution engine, processing ladder logic and managing I\/O states in real-time. Deterministic network performance is achieved by synchronizing the internal scan cycle with the backplane communication throughput. Firmware flash compatibility is essential to ensure that the CPU correctly supports the expanded instruction set and communication protocols required for seamless integration into larger PLC or DCS networks.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the IC200UAL006 support expansion I\/O modules?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the unit is designed to interface with additional Versamax I\/O modules via the side-mounted expansion bus, allowing for I\/O density scaling as application requirements grow.\u003c\/p\u003e\n\u003cp\u003eQ: What is the procedure for restoring the default configuration on the CPU?\u003c\/p\u003e\n\u003cp\u003eA: Users can clear the memory and reset the controller to factory defaults via the programming software port, provided the hardware physical security key-switch is positioned to allow memory modification.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the controller on a 35 mm DIN rail in an orientation that allows for adequate airflow around the heat dissipation vents on the chassis.\u003c\/li\u003e\n\u003cli\u003eVerify that the 24 VDC input power is properly regulated and protected by an external fuse to prevent damage to the internal power supply circuits.\u003c\/li\u003e\n\u003cli\u003eEnsure all communication cabling is shielded and that the shield drain wire is connected to a low-impedance earth ground to prevent signal corruption in industrial environments.\u003c\/li\u003e\n\u003cli\u003eUse a calibrated screwdriver to tighten terminal screws to the recommended torque specification, ensuring secure wire retention without damaging the terminal housing.\u003c\/li\u003e\n\u003cli\u003eConsult the status LEDs (e.g., Run, Stop, Fault) during power-up to confirm the controller has successfully performed its self-diagnostic routine before transitioning to run mode.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52443309211960,"sku":"IC200UAL006","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IC200UAL006.jpg?v=1780299293","url":"https:\/\/www.automodulexpert.com\/products\/ic200ual006-ge-fanuc-micro-plc-datasheet-technical-manual","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}