{"product_id":"ic200uex214-b-ge-fanuc-micro-plc-expansion-module-new-original-stock","title":"IC200UEX214-B GE Fanuc Micro PLC Expansion Module New \u0026 Original Stock","description":"\u003cp\u003eConfigured for high-density I\/O expansion in industrial control platforms, the \u003cstrong\u003eGE IC200UEX214-B\u003c\/strong\u003e (\u003cstrong\u003eIC200UEX214-B\u003c\/strong\u003e Micro PLC Expansion Module) provides direct physical\/electrical execution for 28 discrete I\/O points within the VersaMax Micro architecture.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eIC200UEX214-B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eOrigin\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eSubject to factory batch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eStandard Micro module weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eStandard VersaMax Micro footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eRequires 24 VDC external supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eTotal I\/O Points\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e28\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eDC Inputs\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e16 points, 24 VDC, sourcing logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003eDC Outputs\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003e12 points, 24 VDC, 0.5 A max per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003e18–30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIndustrial Control Communication and I\/O Scaling\u003c\/h3\u003e\n\u003cp\u003eThe module integrates with the host VersaMax Micro controller via the dedicated expansion port, maintaining consistent backplane bus communication velocity. The architecture supports efficient I\/O density scaling, allowing for the addition of sourcing logic inputs and outputs without compromising the deterministic cycle time of the primary PLC scan. Field I\/O is galvanically isolated from the internal logic circuitry to protect the controller from transient surges and ground loops.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can this module be hot-swapped during operation?\u003c\/p\u003e\n\u003cp\u003eA: No, the VersaMax Micro expansion bus does not support hot-swapping. The power supply must be cycled or the controller placed in a stop mode before connecting or disconnecting the expansion cable.\u003c\/p\u003e\n\u003cp\u003eQ: Are the outputs protected against overcurrent conditions?\u003c\/p\u003e\n\u003cp\u003eA: Each output is designed to drive loads up to 0.5 A. Users should implement external fusing or circuit protection to prevent damage to the output transistors in the event of a field short circuit.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure all power to the PLC and expansion modules is removed before installation or cabling.\u003c\/li\u003e\n\u003cli\u003eMount the module on a 35 mm DIN rail or directly to the panel using the designated mounting holes to ensure vibration resistance.\u003c\/li\u003e\n\u003cli\u003eConnect the module to the base unit using the manufacturer-supplied expansion cable, ensuring the locking mechanism is fully engaged.\u003c\/li\u003e\n\u003cli\u003eConnect the 24 VDC external power supply to the designated terminals, verifying that the polarity matches the sourcing logic requirements.\u003c\/li\u003e\n\u003cli\u003eUtilize the integrated LED indicators to verify active signal states for each input and output channel during commissioning.\u003c\/li\u003e\n\u003cli\u003eMaintain proper wire management to keep signal lines separated from power-carrying conductors to prevent electrical noise interference.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52426085663032,"sku":"IC200UEX214-B","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IC200UEX214-B2.jpg?v=1779699801","url":"https:\/\/www.automodulexpert.com\/products\/ic200uex214-b-ge-fanuc-micro-plc-expansion-module-new-original-stock","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}