{"product_id":"ic200uex626-d-ge-fanuc-analog-expansion-module-new-original-stock","title":"IC200UEX626-D GE Fanuc Analog Expansion Module New \u0026 Original Stock","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC200UEX626-D\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC200UEX626-D\u003c\/strong\u003e Analog Expansion Module, operates as a dedicated hardware component for multi-range signal processing within VersaMax Micro platform networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eIC200UEX626-D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eOrigin\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eSubject to factory batch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e0.425 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e101.6 x 88.9 x 50.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e4 differential (0–10 VDC, ±10 VDC, 0–20 mA, 4–20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e2 single-ended (0–10 VDC, 0–20 mA, 4–20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003eResolution\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003e12-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eBackplane Bus Communication and Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe module integrates via the expansion port to provide real-time signal conversion for the host controller. The backplane bus communication velocity is optimized to ensure low-latency data acquisition, allowing the module to report analog values within the scan cycle. Firmware flash compatibility is managed by the host system to ensure alignment with existing project configurations. The module utilizes high-density I\/O density scaling techniques to process multiple signal types simultaneously, ensuring consistent accuracy across all 6 channels.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can this module be installed at a distance from the host controller?\u003c\/p\u003e\n\u003cp\u003eA: The module supports remote installation at distances up to 2 meters using the manufacturer-specified expansion cabling.\u003c\/p\u003e\n\u003cp\u003eQ: Are the analog inputs galvanically isolated from the controller?\u003c\/p\u003e\n\u003cp\u003eA: The inputs are designed with differential architecture to mitigate common mode noise up to ±40 V, but users should verify grounding requirements to maintain signal integrity.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the module securely on a DIN rail or flat surface using the integrated mounting points.\u003c\/li\u003e\n\u003cli\u003eUtilize shielded, twisted-pair cabling for all analog signals to minimize electromagnetic interference and crosstalk.\u003c\/li\u003e\n\u003cli\u003eConnect the cable shield to a single point chassis ground at the cabinet entry to maintain signal common mode rejection.\u003c\/li\u003e\n\u003cli\u003eEnsure the 24 VDC power supply operates within the 19.2–30 VDC range to prevent operational instability.\u003c\/li\u003e\n\u003cli\u003eInspect the diagnostic LED indicators during power-up to confirm the module is communicating correctly with the host controller.\u003c\/li\u003e\n\u003cli\u003eConfirm that the voltage or current range switches are set correctly for each channel before applying field signals.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52426106077496,"sku":"IC20UEX626-D","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IC20UEX626-D2.jpg?v=1779781439","url":"https:\/\/www.automodulexpert.com\/products\/ic200uex626-d-ge-fanuc-analog-expansion-module-new-original-stock","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}