{"product_id":"ic660bba026m-genius-i-o-analog-input-block-ge-fanuc","title":"IC660BBA026M Genius I\/O Analog Input Block GE Fanuc","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC660BBA026M\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC660BBA026M\u003c\/strong\u003e Analog Input Block, operates as a dedicated hardware component for interfacing 4-20 mA current-source signals within Genius I\/O network platforms. This block manages six isolated input circuits, providing programmable resolution and conversion timing to facilitate precise signal processing from field devices. It functions by converting analog current inputs into digital values for transmission to the host controller via the Genius protocol.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC660BBA026M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eConsult Factory Documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.8 kg (4 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e224.3 mm x 88.9 mm x 100.1 mm (8.83\" x 3.50\" x 3.94\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial Standard Range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24\/48 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e6 isolated channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Range\u003c\/td\u003e\n\u003ctd\u003e4-20 mA, 0-25 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Accuracy\u003c\/td\u003e\n\u003ctd\u003e0.1 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Time\u003c\/td\u003e\n\u003ctd\u003e16 ms to 400 ms (Programmable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane bus communication velocity and firmware compatibility\u003c\/h3\u003e\n\u003cp\u003eThe IC660BBA026M module integrates into the Genius I\/O field bus, requiring precise synchronization of the backplane bus communication velocity to maintain deterministic network performance. Users must ensure that the communication settings in the master controller match the baud rate and bus timing parameters of the block to prevent cyclic communication timeouts. Firmware flash compatibility should be verified during system integration, as specific controller revisions may necessitate matching I\/O block firmware versions to enable advanced diagnostic reporting and programmable alarm limit functionality.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Is it possible to modify the conversion time of the analog inputs?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the conversion time is software-programmable and can be configured between 16 ms and 400 ms via the handheld monitor or CPU datagrams to balance response speed and signal filtering.\u003c\/p\u003e\n\u003cp\u003eQ: Are the input channels electrically isolated from each other?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the six input circuits are individually isolated. This design prevents common-mode noise and ground loop interference between multiple field instruments connected to the same block.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the block on a standard industrial DIN-rail or flat surface, ensuring adequate clearance around the enclosure to facilitate airflow and heat dissipation.\u003c\/li\u003e\n\u003cli\u003eTerminate 4-20 mA signal wiring using shielded twisted-pair cables, ensuring the shield is grounded at a single point to minimize electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003eVerify that the DC power supply input remains within the 18-56 VDC operating range; voltage drops along long cable runs must be calculated to ensure the block receives minimum required potential.\u003c\/li\u003e\n\u003cli\u003eDuring wiring, ensure that the current-source devices are properly matched to the input impedance of the block to maintain the specified 0.1 % accuracy.\u003c\/li\u003e\n\u003cli\u003eBefore placing the module into full operation, verify that the Genius bus address switches are correctly set to avoid addressing conflicts on the multidrop network.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52635926757688,"sku":"IC660BBA026M","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IC660BBA104.jpg?v=1783930628","url":"https:\/\/www.automodulexpert.com\/products\/ic660bba026m-genius-i-o-analog-input-block-ge-fanuc","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}